Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HRA III (DBA) LAKE SHORE COMMONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HRA III (DBA) LAKE SHORE COMMONS in 1402 HOSPITAL PLAZA DR., WILMINGTON, NC 28401 (NAICS 623110). OSHA activity number 306926338.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HRA III (DBA) Lake Shore Commons — free Get an email when a new federal OSHA severe-injury report for HRA III (DBA) Lake Shore Commons is published. One employer, no account, unsubscribe in one click.
Site address
1402 HOSPITAL PLAZA DR.
City
WILMINGTON
State
NC
ZIP
28401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
623110
SIC code (legacy)
8059
Employees
300
Ownership type
A
Industry flags
Manufacturing safety.

2 citations on file for this inspection.

95012901

Serious 1 instance 4 exposed
Issued
Dec 2, 2003
Abate by
Dec 29, 2003
Penalty
Initial $963 · Current $771 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees in that employees
were exposed to:
ref:  National Electric Code 1999 517-20 (a)
a)facility, kitchen - 120 volt ac duplex receptacle located above a double
deep sink was not equipped with
a ground fault interrupter.
Among other methods , one feasible and acceptable abatement method to
correct this hazard is to
install a ground fault interrupter.
Recent events (2)
  • — I (S) $771.00
  • — Z (S) $963.00

1910.157 E02

Other-than-serious 1 instance 20 exposed
Issued
Dec 2, 2003
Abate by
Dec 29, 2003
Recent events (2)
  • — I (O)
  • — Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306926338.