GOSHEN, NY —
OSHA Inspection: GOSHEN VILL POLICE DEPT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GOSHEN VILL POLICE DEPT in 1 GRAND ST, GOSHEN, NY 10924 (NAICS 922120). OSHA activity number 306987892.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOSHEN VILL POLICE DEPT
- Site address
- 1 GRAND ST
- City
- GOSHEN
- State
- NY
- ZIP
- 10924
- Mailing
- 1 GRAND ST, GOSHEN, NY 10924
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922120
- SIC code (legacy)
- 9221
- Employees
- 25
- Ownership type
- B
Citations
17 citations on file for this inspection.
3A0001
- Issued
- Oct 15, 2010
- Abate by
- Dec 15, 2010
General-duty citation text
NYSLL Article 2, Section 27-a.3.a(1): The employer did not furnish to each of its employees, employment and a place of employment which was free from recognized hazards that are causing or were likely to cause death or serious physical harm to its employees and which will provide reasonable and adequate protection to the lives, safety or health of its employees. In applying this paragraph, fundamental distinctions between private and public employment have been recognized. Employees were exposed to the hazard of crushing injury or death when entering/exiting through the overhead door. Among other methods, three reasonable and adequate abatement methods to correct the hazard are: (1) A constant pressure actuation switch. This would always be operated in sight so that it could be released and manually reversed before an obstruction was hit. (2) Installation of a reversing edge switch. This would allow an automatic closing control out of sight of the door, but would immediately reverse the direction of the door upon striking an obstruction. A variation to this option would be to use photoelectric cells that would reverse the door when an obstruction was encountered by the beam. (3) A three button control switch. If the following conditions are met: a) It is provided with a permanent placard adjacent to the switch with the following warning letters at least 1/4" high: - WARNING - - TO PREVENT ENTRAPMENT - DO NOT START THE DOOR DOWNWARD UNLESS THE DOORWAY IS CLEAR b) The control station and placard are located within sight of the doorway. c) Automatic closing controls are not also installed. d) Operator must remain at the control station and observe the door until the door is fully closed. a) Goshen Vill Police Dept - The garage door, located at police headquarters was not equipped with any safety features and using the door could cause serious physical harm.
1910.36 D01
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.36 G02
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.37 B06
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.157 C01
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.176 C
- Issued
- Oct 15, 2010
- Abate by
- Nov 10, 2010
1910.303 F02
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.304 F01 IV
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.305 B01 II
- Issued
- Oct 15, 2010
- Abate by
- Nov 3, 2010
1910.134 C01 IX
- Issued
- Oct 15, 2010
- Abate by
- Dec 8, 2010
1910.134 C01 III
- Issued
- Oct 15, 2010
- Abate by
- Dec 8, 2010
1910.176 B
- Issued
- Oct 15, 2010
- Abate by
- Nov 24, 2010
1910.1030 C01 IIB
- Issued
- Oct 15, 2010
- Abate by
- Dec 8, 2010
1910.1030 C01 IV
- Issued
- Oct 15, 2010
- Abate by
- Dec 8, 2010
1910.1200 E01
- Issued
- Oct 15, 2010
- Abate by
- Dec 15, 2010
1910.1200 E01 I
- Issued
- Oct 15, 2010
- Abate by
- Dec 15, 2010
1910.1200 G08
- Issued
- Oct 15, 2010
- Abate by
- Dec 15, 2010
More inspections at Goshen Vill Police Dept
View Goshen Vill Police Dept's full OSHA safety record →
More inspections in this industry (NAICS 922120)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306987892.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.