Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: L & G PUMPING UNIT SERVICE, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of L & G PUMPING UNIT SERVICE, INC. in I-10 & FT. STOCKTON/SIXMILE DRAW LEASE WELL #1-4, FORT STOCKTON, TX 79735 (NAICS 213112). OSHA activity number 307008540.

Watch L & G Pumping Unit Service, INC. — free Get an email when a new federal OSHA severe-injury report for L & G Pumping Unit Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
I-10 & FT. STOCKTON/SIXMILE DRAW LEASE WELL #1-4
City
FORT STOCKTON
State
TX
ZIP
79735
Mailing
2000 RANKIN HWY, MIDLAND, TX 79701
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
5
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $1500.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized
hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the condition(s) listed below:
a) Sixmile Draw, Lease Well #1-4, Ft. Stockton, TX; On or about 5-25-05 a
Lufkin pumping
unit, model number C320D-305-100, serial number C30254-F-311919, was not
disassembled
according to the manufacturer's specifications, American Petroleum
Institute (API) RP 54
guidelines and/or general industry practice. The oil pumping unit was in
the process of being
disassembled when the counter-weights unexpectedly rotated downward
crushing an employee
to death. The employer did not secure the counter-weights. The employer
had not established
and/or implemented an energy control program consisting of energy control
procedures to ensure
that prior to servicing and/or maintenance operations machinery and/or
equipment was isolated
or otherwise rendered inoperative.
Among other methods, one method of abatement is to ensure that employees
follow the
specifications and/or instructions referenced in the  operator's manual
and sections 1.3, 6.8, 6.9
and 11 of API RP 54, Third Edition, 1999.

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307008540.