SEMINOLE, TX —
OSHA Inspection: PIONEER GIN INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PIONEER GIN INC. in 18 MILES W SEMINOLE HWY 180, SEMINOLE, TX 79360 (NAICS 115111). OSHA activity number 307010082.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PIONEER GIN INC.
- Site address
- 18 MILES W SEMINOLE HWY 180
- City
- SEMINOLE
- State
- TX
- ZIP
- 79360
- Mailing
- ROUTE 4 BOX 414, SEMINOLE, TX 79360
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115111
- SIC code (legacy)
- 0724
- Employees
- 24
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 11, 2006
- Abate by
- Feb 7, 2006
- Penalty
- Initial $525 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Pioneer Gin, Inc., Route 4 Box 414, Seminole, TX. For the period of time up to and including 12/02/05, employees were not protected from electrical hazards due to the following condition: A 110-volt outlet indicated a no ground condition when tested. Under the National Electric Code (NEC 2005), Article 547.9(B)(3)(a) states "The grounded circuit conductor shall be connected to the building disconnecting means and to the grounding electrode system of that building or structure where all the requirements of 250.32(B)(2) are met." One feasible and acceptable abatement method would be to ensure all electrical equipment is installed / maintained in accordance with Article 547 of the National Electric Code. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $315.00
- — Z (S) $525.00
5(a)(1)
- Issued
- Jan 11, 2006
- Abate by
- Apr 12, 2006
- Penalty
- Initial $525 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Pioneer Gin, Inc., Route 4 Box 414, Seminole, TX. For the period of time up to and including 12/02/05, employees were not protected from fall hazards due to the following conditions: a) The ladder access entry at the #3 and #4 stick machines did not have a chain / door. b) The catwalk near the incline cleaner had a 68-inch span without a guardrail. c) The stairway leading to the area under the press did not have a midrail in place. d) A floor hole at the #1 gin stand was not guarded. e) Two floor holes in the screw auger / conveyor area of the module feeder were not guarded. Under the American National Standard A12.1 1973, paragraph 5.2 states "Every runway shall be guarded by a railing (or the equivalent as specified in 7.3) on all open sides 4 feet or more above floor or ground level." Under the American National Standard A12.1 1973, paragraph 7.1 states "A guard railing shall consist of top rail, intermediated rail or equivalent protection, and posts, and shall have a vertical height within the range of 36 inches to 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level." Under the American National Standard A12.1 1973, paragraph 7.2 states "A stair railing shall be of construction similar to a guard railing, but the vertical height shall be not more than 42 inches or less than 30 inches from the upper surface of the top rail to the surface of the tread in line with the face of the riser at the forward edge of the tread." Under the American National Standard A12.1 1973, paragraph 3.2 states "Every ladderway floor opening or platform shall be guarded by a guard railing with a toeboard on all exposed sides (except entrance to opening), and with the passage through the railing provided so that a person cannot walk directly into the opening." Under the American National Standard A12.1 1973, paragraph 3.8 states "Every floor hole shall be guarded by either (1) a railing with toeboard on all exposed sides, or (2) a floor hole cover of sufficient strength. While the cover is not in place, the floor hole shall be attended or shall be protected by a removable guard railing." One feasible and acceptable abatement method would be to ensure all walking / working surfaces are installed / maintained in accordance with A12.1 of the American National Standards. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $315.00
- — Z (S) $525.00
5(a)(1)
- Issued
- Jan 11, 2006
- Abate by
- Apr 12, 2006
- Penalty
- Initial $525 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Pioneer Gin, Inc., Route 4 Box 414, Seminole, TX. For the period of time up to and including 12/02/05, employees were not protected from fire hazards due to the following conditions: a) Three oxygen and four acetylene compressed gas cylinders were stored together. b) The oxygen and acetylene compressed gas cylinders were not stored in a protected area. Under the American National Standard Z49.1 1973, paragraph 3.2.3.3 states "Oxygen cylinders in storage shall be separated from fuel-gas cylinders, reserve socks of carbides, or highly combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour." Under the American National Standard Z49.1 1973, paragraph 3.2.3.5.1 states "Cylinders shall be stored away from elevators, stairs or gangways in assigned places where cylinders will not be knocked over or damaged by passing or falling objects." One feasible and acceptable abatement method would be to ensure employees are trained and comprehend Z49.1 of the American National Standards regarding welding and cutting operations and safety. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $315.00
- — Z (S) $525.00
1928.57 A06
- Issued
- Jan 11, 2006
- Abate by
- Jan 24, 2006
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
1928.57 D01 IV
- Issued
- Jan 11, 2006
- Abate by
- Apr 12, 2006
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1928.57 D01 V
- Issued
- Jan 11, 2006
- Abate by
- Apr 12, 2006
1928.57 D01 VII
- Issued
- Jan 11, 2006
- Abate by
- Apr 12, 2006
1928.57 D02 II
- Issued
- Jan 11, 2006
- Abate by
- Apr 12, 2006
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — I (S) $1500.00
- — Z (S) $2500.00
More inspections in this industry (NAICS 115111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307010082.