WELLINGTON, TX —
OSHA Inspection: FARMERS COOPERATIVE GIN - BUSINESS OFFICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FARMERS COOPERATIVE GIN - BUSINESS OFFICE in MANGUM HIGHWAY, WELLINGTON, TX 79095 (NAICS 115111). OSHA activity number 307010157.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FARMERS COOPERATIVE GIN - BUSINESS OFFICE
- Site address
- MANGUM HIGHWAY
- City
- WELLINGTON
- State
- TX
- ZIP
- 79095
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115111
- SIC code (legacy)
- 0724
- Employees
- 40
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 6, 2006
- Abate by
- Mar 30, 2006
- Penalty
- Initial $875 · Current $525 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: For the period of time up to and including 12/08/05, employees were not protected from electrical hazards due to the following condition: a) An electrical panel box containing circuit breakers near the lint cleaner had openings in the front, thus permitting combustible cotton lint to accumulate on the circuit breakers and exposing employees to contact with electrical current. b) An electrical panel box containing circuit breakers near the bale press area was equipped with a makeshift front panel made out of cardboard and tape. Employees were exposed to the hazards of fire from ignition of cotton lint and electrical shock from contact with the current. Under the National Electric Code (NEC 2005), Article 547.5(C)(1) states "Equipment enclosures, boxes, conduit bodies, and fittings installed in areas of buildings where excessive dust may be present shall be designed to minimize the entrance of dust and shall have not openings (such as holes for attachment screws) through which dust could enter the enclosure. One feasible and acceptable abatement method would be to ensure all electrical equipment is installed / maintained in accordance with Article 547 of the National Electric Code. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00