BROWNFIELD, TX —
OSHA Inspection: LONE STAR AG INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LONE STAR AG INCORPORATED in 2253 US HWY 380, BROWNFIELD, TX 79316 (NAICS 115111). OSHA activity number 307010181.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LONE STAR AG INCORPORATED
- Site address
- 2253 US HWY 380
- City
- BROWNFIELD
- State
- TX
- ZIP
- 79316
- Mailing
- RT 1 BOX 101, BROWNFIELD, TX 79316
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115111
- SIC code (legacy)
- 0724
- Employees
- 28
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 23, 2005
- Abate by
- Jan 23, 2006
- Penalty
- Initial $525 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Lone Star Ag Inc., 2253 US Hwy 380, Brownfield, TX. For the period of time up to and including 12/06/05, employees were not protected from electrical hazards due to the following conditions: a) A 110-volt outlet was being supported by the inner conductors. b) A 220-volt outlet was pulled from the strain relief. c) A 220-volt flexible cord was incorrectly spliced. d) All unused openings in an electric panel box were not closed. Under the National Electric Code (NEC 2005), Article 547.5(E) states "All electrical wiring and equipment subject to physical damage shall be protected." Under the National Electric Code (NEC 2005), Article 547.6 states "Switches, including pushbuttons, relays, and similar devices, receptacles, circuit breakers, controllers, and fuses shall be provided with enclosures as specified in 547.5(C)." Under the National Electric Code (NEC 2005), Article 547.5(C)(1) states "Equipment enclosures, boxes, conduit bodies, and fittings installed in areas of buildings where excessive dust may be present shall be designed to minimize the entrance of dust and shall have not openings (such as holes for attachment screws) through which dust could enter the enclosure. One feasible and acceptable abatement method would be to ensure all electrical equipment is installed / maintained in accordance with Article 547 of the National Electric Code. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $315.00
- — Z (S) $525.00
5(a)(1)
- Issued
- Dec 23, 2005
- Abate by
- Jan 6, 2006
- Penalty
- Initial $525 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Lone Star Ag inc., 2253 US Hwy 380, Brownfield, TX. For the period of time up to and including 12/06/05, employees were not protected from fire hazards due to the following conditions: All fire extinguishers in the fire cabinet were not fully charged. Under the National Fire Protection Agency (2002), NFPA 10, Paragraph 1.5.2 states "Portable fire extinguishers shall be maintained in a fully charged and operable condition and shall be kept in their designated places at all times when they are not being used." Under the National Fire Protection Agency (2002), NFPA 10, Paragraph 6.1.3 states "The owner or designated agent or occupant of a property in which fire extinguishers are located shall be responsible for such inspection, maintenance, and recharging." One feasible and acceptable abatement method would be to ensure all fire extinguishers are installed / maintained in accordance with NFPA 10 of the National Fire Protection Agency Standards. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $315.00
- — Z (S) $525.00
1928.57 D01 V
- Issued
- Dec 23, 2005
- Abate by
- Mar 28, 2006
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1928.57 D01 IV
- Issued
- Dec 23, 2005
- Abate by
- Mar 28, 2006
1928.57 D02 II
- Issued
- Dec 23, 2005
- Abate by
- Mar 28, 2006
More inspections in this industry (NAICS 115111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307010181.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.