SEMINOLE, TX —
OSHA Inspection: OASIS GIN INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OASIS GIN INC. in 810 COUNTY ROAD 331, SEMINOLE, TX 79360 (NAICS 115111). OSHA activity number 307010421.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OASIS GIN INC.
- Site address
- 810 COUNTY ROAD 331
- City
- SEMINOLE
- State
- TX
- ZIP
- 79360
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115111
- SIC code (legacy)
- 0724
- Employees
- 57
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 9, 2006
- Abate by
- Feb 3, 2006
- Penalty
- Initial $525 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Oasis Gin Inc., 810 County Road 331, Seminole, TX. For the period of time up to and including 01/06/06, employees were not protected from electrical hazards due to the following conditions: A flexible cord was used instead of permanent wiring. This cord passed through two switch boxes without protection. Under the National Electric Code (NEC 2005), Article 547.5(D) states "Where necessary to employ flexible connections, dusttight flexible connectors, liquidtight flexible conduit, or flexible cord listed and identified for hard usage shall be used. All connectors and fittings used shall be listed and identified for the purpose." Under the National Electric Code (NEC 2005), Article 547.5(C)(1) states "Equipment enclosures, boxes, conduit bodies, and fittings installed in areas of buildings where excessive dust may be present shall be designed to minimize the entrance of dust and shall have not openings (such as holes for attachment screws) through which dust could enter the enclosure. One feasible and acceptable abatement method would be to ensure all electrical equipment is installed / maintained in accordance with Article 547 of the National Electric Code. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $315.00
- — Z (S) $525.00
1928.57 D02 II
- Issued
- Jan 9, 2006
- Abate by
- Apr 10, 2006
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
More inspections in this industry (NAICS 115111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307010421.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.