ANDREWS, TX —
OSHA Inspection: LANTERN DRILLING CO. SUBSIDIARY OF FOREST OIL CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LANTERN DRILLING CO. SUBSIDIARY OF FOREST OIL CORP in ATP #6, ANDREWS, TX 79766 (NAICS 211111). OSHA activity number 307011338.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LANTERN DRILLING CO. SUBSIDIARY OF FOREST OIL CORP
- Site address
- ATP #6
- City
- ANDREWS
- State
- TX
- ZIP
- 79766
- Mailing
- 1101 EAST POOL, ODESSA, TX 79766
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211111
- SIC code (legacy)
- 1311
- Employees
- 114
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 20, 2006
- Abate by
- May 2, 2006
- Penalty
- Initial $1,375 · Current $1,375
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Lantern Drilling Rig 9, HSA 1649, Monahans, TX. For the period of time up to and including 03/03/06, equipment on location was not properly grounded in the following instances: a) The ground rod ("electrode") on the accumulator was in the soil less than six inches. The electrode was less than 3-feet in length. b) The ground rod ("electrode") on the fuel tank was not in the soil and the grounding electrode conductor was not attached between the fuel tank and the electrode. The electrode was less than 3-feet in length. c) The ground rod ("electrode") on mud pump #2 was in the soil less than six inches and the grounding electrode conductor was not attached between the mud pump and the electrode. The electrode was less than 3-feet in length. According to API Recommended Practice 54, August 1999, section 6, paragraph 6.1.16 states "The rig substructure, derrick, mast, and other equipment as appropriate, shall be grounded to prevent accumulation of a static charge." According to NEC 2005, Article 250, section 53, paragraph (G) states "The electrode shall be installed such that at least 2.44 m (8 ft) of length is in contact with the soil. It shall be driven to a depth of not less than 2.44 m (8 ft) except that, where rock bottom is encountered, the electrode shall be driven at an oblique angle not to exceed 45 degrees from the vertical or, where rock bottom is encountered at an angle up to 45 degrees, the electrode shall be permitted to be buried in a trench that is at least 750 mm (30 in.) deep. The upper end of the electrode shall be flush with or below ground level unless the aboveground end and the grounding electrode conductor attachment are protected against physical damage as specified in 250.10." Among other methods, feasible and acceptable methods for abated would be: 1) Ensure all "electrodes" are not less than 8-feet in length. 2) Ensure all "electrodes" are used according to the NEC. 3) Ensure all equipment is properly grounded after each rig-up. 4) Follow the method of grounding recommended in IADC Alert 98-22.
1910.212 A01
- Issued
- Apr 20, 2006
- Abate by
- May 2, 2006
- Penalty
- Initial $825 · Current $825
1910.304 F04
- Issued
- Apr 20, 2006
- Abate by
- May 2, 2006
- Penalty
- Initial $825 · Current $825
1910.305 B01
- Issued
- Apr 20, 2006
- Abate by
- May 2, 2006
More inspections at Lantern Drilling CO. Subsidiary of Forest OIL Corp
View Lantern Drilling CO. Subsidiary of Forest OIL Corp's full OSHA safety record →
More inspections in this industry (NAICS 211111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307011338.