MENTOR, OH ·
OSHA Inspection: L J MFG.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of L J MFG. in 6345 CARNEGIE ST, MENTOR, OH 44060 (NAICS 333514). OSHA activity number 307026633.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- L J MFG.
- Site address
- 6345 CARNEGIE ST
- City
- MENTOR
- State
- OH
- ZIP
- 44060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333514
- SIC code (legacy)
- 3544
- Employees
- 7
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 15, 2003
- Abate by
- Nov 20, 2003
- Penalty
- Initial $450 · Current $315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: In the warehouse section of the facility, the employer was transporting above ground compressed air at 80-100 PSI through 3/4 inch regular LCP National 1185,schedule 40 1120 polyvinyl chloride (PVC) pipes. The PVC pipe was used to supply compressed air to five (5) CNC machines with PVC lines feeding into the CNC machines at waist level. These lines also are used to feed air hoses used by employees daily. Among other methods, the following are feasible and acceptable methods to minimize the probability of injury during the transfer of compressed air throughout the facility. 1. Follow American Society for Testing and Materials (ASTM) Standard D1785-86, which states polyvinyl chloride (PVC), pipes can be used for transportation of compressed air and gases only if the PVC pipes made of shatter resistant material or are encased in a shatter resistant material. 2. Follow American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.8-198 Gas Transmission and Distribution Piping Systems Standard, sections 842.32, 842.43 and 849.52(b) which limits the operating pressure of plastic piping distributions systems to 100 pounds per square inch (psi) and prohibits the installation of such systems above ground except where " the above ground portion of the plastic service line is completely enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration." 3. Replace all existing PVC pipes with a cast iron or other type of metal type piping rated to transport compressed air safely above ground.
Recent events (2)
- · I (S) $315.00
- · Z (S) $450.00
1910.178 L
- Issued
- Sep 15, 2003
- Abate by
- Nov 20, 2003
- Penalty
- Initial $450 · Current $315 Reduced
Recent events (2)
- · I (S) $315.00
- · Z (S) $450.00
1910.110 F02 I
- Issued
- Sep 15, 2003
- Abate by
- Sep 18, 2003
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 H
- Issued
- Sep 15, 2003
- Abate by
- Sep 18, 2003
X1000070
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 333514)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 307026633.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.