FRANKLIN PARK, IL —
OSHA Inspection: FABTEC MANUFACTURING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FABTEC MANUFACTURING, INC. in 9896 FRANKLIN AVE, FRANKLIN PARK, IL 60131 (NAICS 332999). OSHA activity number 307096271.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FABTEC MANUFACTURING, INC.
- Site address
- 9896 FRANKLIN AVE
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- SIC code (legacy)
- 3599
- Employees
- 18
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 30, 2003
- Abate by
- Dec 15, 2003
- Penalty
- Initial $750 · Current $400 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the rotating blade: a)Main Shop Area-The Work-O-Matic Vertical Bandsaw bandsaw No model#, was not equipped with a magnetic restarter or similar device, as prescribed by American National Standards Institute (ANSI) B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply such a device would prevent the saw from restarting automatically when power is restored. b)Main Shop Area-The RYOBI 14" Metal Cut off saw Serial# 080277, was not equipped with a magnetic restarter or similar device, as prescribed by American National Standards Institute (ANSI) B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply such a device would prevent the saw from restarting automatically when power is restored. c)Main Shop Area- The No Named 16" Cut off Saw model 2416, was not equipped with a magnetic restarter or similar device, as prescribed by American National Standards Institute (ANSI) B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply such a device would prevent the saw from restarting automatically when power is restored. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $400.00
- — Z (S) $750.00
1910.212 A01
- Issued
- Oct 30, 2003
- Abate by
- Dec 15, 2003
- Penalty
- Initial $1,500 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1500.00
1910.215 A02
- Issued
- Oct 30, 2003
- Abate by
- Dec 15, 2003
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
1910.215 A04
- Issued
- Oct 30, 2003
- Abate by
- Dec 15, 2003
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
1910.215 B09
- Issued
- Oct 30, 2003
- Abate by
- Nov 26, 2003
1910.219 D01
- Issued
- Oct 30, 2003
- Abate by
- Dec 15, 2003
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
1910.219 E03 I
- Issued
- Oct 30, 2003
- Abate by
- Nov 26, 2003
More inspections at Fabtec Manufacturing, INC.
View Fabtec Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307096271.