Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROBERT C. WEISHEIT CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROBERT C. WEISHEIT CO., INC. in 1011 SESAME STREET, FRANKLIN PARK, IL 60131 (NAICS 332999). OSHA activity number 307107250.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Robert C. Weisheit CO., INC. — free Get an email when a new federal OSHA severe-injury report for Robert C. Weisheit CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1011 SESAME STREET
City
FRANKLIN PARK
State
IL
ZIP
60131
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
SIC code (legacy)
3599
Employees
18
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 2 instances 2 exposed
Issued
Nov 13, 2003
Abate by
Dec 10, 2003
Penalty
Initial $750 · Current $373 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the rotating blade:
a)Main Shop Area-The Grob Inc.Verrtical Bandsaw Type NS24, was not
equipped with a
magnetic restarter or similar device, as prescribed by American National
Standards Institute
(ANSI) B11.10-1990, Section 5.2.3.4, that in the event of an interruption
in the electrical supply
such a device would prevent the saw from restarting automatically when
power is restored.
b)Main Shop Area-The Rusch Horizontial Bandsaw Serial# HBS250, was not
equipped with a
magnetic restarter or similar device, as prescribed by American National
Standards Institute
(ANSI) B11.10-1990, Section 5.2.3.4, that bin the event of an interruption
in
the electrical
supply such a device would prevent the saw from restarting automatically
when power is
restored.
In accordance with 29 CFR 1903.19(d), abatement certification is required
for this violation
(using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in
addition, documentation demonstrating that abatement is complete must be
included with
your certification. This documentation may include, but is not limited to,
evidence of the
purchase or repair of the equipment, photographic or video evidence of
abatement, or other
written records.
Recent events (2)
  • — I (S) $373.00
  • — Z (S) $750.00

1910.212 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Nov 13, 2003
Abate by
Dec 10, 2003
Penalty
Initial $1,500 · Current $425 Reduced
Recent events (2)
  • — I (S) $425.00
  • — Z (S) $1500.00

1910.219 B01

Serious Gravity 02 1 instance 1 exposed
Issued
Nov 6, 2003
Abate by
Dec 4, 2003
Penalty
Initial $600 · Current $210 Reduced
Recent events (2)
  • — I (S) $210.00
  • — Z (S) $600.00

View Robert C. Weisheit CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307107250.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.