Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: QUANTERGY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUANTERGY, INC. in 2230 MARVYN PARKWAY, OPELIKA, AL 36804 (NAICS 334419). OSHA activity number 307153700.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quantergy, INC. for free Get an email when a new federal OSHA severe-injury report for Quantergy, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
QUANTERGY, INC.
Site address
2230 MARVYN PARKWAY
City
OPELIKA
State
AL
ZIP
36804
Mailing
PO BOX 190, OPELIKA, AL 36803
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
SIC code (legacy)
3679
Employees
281
Ownership type
Private (A)
Industry flags
Manufacturing health.

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 01 1 instance 2 exposed
Issued
May 4, 2004
Abate by
May 22, 2004
Penalty
Initial $1,125 · Current $1,125

Hazardous substances L129

Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish
employmnent and a place of employment which were free from recognized
hazards that were causing or likely
to cause death or serious physical harm to employees in that employees
were exposed to:
(a)In the reclaim area: On or about 3/18/04, and for approximately three
years prior, employees were
exposed to irritating solvent vapors of d-limonene which causes headaches,
nausea, burning of the
eyes, nose and throat because the downdraft exhaust ventilation system on
the reclaim workbench was
not working.
Among other methods, one feasible and acceptable method to correct this
hazard is to conduct peroidic
inspection and testing of the mechanical components of the exhaust
ventilation system and measure the flow
rate or the static pressure of the system as recommended in Chapter 9 of
"Industrial Ventilation, A Manual Of
Recommended Practice, 23rd Edition, ACGIH" to insure that the system is
working properly as designed.

1910.132 C

Serious Gravity 01 1 instance 2 exposed
Issued
May 4, 2004
Abate by
May 11, 2004
Penalty
Initial $1,125 · Current $1,125

Hazardous substances L129

1910.151 C

Serious Gravity 01 1 instance 2 exposed
Issued
May 4, 2004
Abate by
May 21, 2004
Penalty
Initial $1,125 · Current $1,125

Hazardous substances L129

1910.1200 F05 II

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
May 4, 2004
Abate by
May 14, 2004

Hazardous substances L129

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 307153700.