CORPUS CHRISTI, TX ·
OSHA Inspection: CABINET DOORS UNLIMITED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CABINET DOORS UNLIMITED in 5821 AYERS, SUITE B, CORPUS CHRISTI, TX 78415 (NAICS 337122). OSHA activity number 307225649.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CABINET DOORS UNLIMITED
- Site address
- 5821 AYERS, SUITE B
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78415
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337122
- SIC code (legacy)
- 2511
- Employees
- 5
- Ownership type
- Private (A)
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 4, 2004
- Abate by
- Mar 18, 2004
- Penalty
- Initial $450 · Current $270 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards of fly debris: At this location throughout the shop, employees were exposed to the hazards of flying shards in that the shop air was piped through this facility via Poly-Vinyl- Chloride (PVC) piping. Plastic pipe is subject to failure and shattering when exposed to the pressures of compressed gases. A means of abatement would be to replace the existing PVC piping with a type suitable for the transmission of compressed gases.
Recent events (2)
- · I (S) $270.00
- · Z (S) $450.00
1910.157 C01
- Issued
- Mar 4, 2004
- Abate by
- Mar 18, 2004
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- · I (S) $360.00
- · Z (S) $600.00
1910.157 C04
- Issued
- Mar 4, 2004
- Abate by
- Mar 18, 2004
Recent events (2)
- · I (S)
- · Z (S)
1910.157 E03
- Issued
- Mar 4, 2004
- Abate by
- Mar 18, 2004
1910.157 E03
- Issued
- Mar 4, 2004
- Abate by
- Mar 18, 2004
- Penalty
- Initial $600 · Current $600
Recent events (2)
- · I (S) $600.00
- · Z (S) $600.00
1910.303 F
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
- Penalty
- Initial $600 · Current $600
Recent events (2)
- · I (S) $600.00
- · Z (S) $600.00
1910.303 G01 I
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
- Penalty
- Initial $600 · Current $600
Recent events (2)
- · I (S) $600.00
- · Z (S) $600.00
1910.303 G02 I
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
- Penalty
- Initial $600 · Current $600
Recent events (2)
- · I (S) $600.00
- · Z (S) $600.00
1910.304 F04
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
- Penalty
- Initial $600 · Current $600
Recent events (2)
- · I (S) $600.00
- · Z (S) $600.00
1910.305 G02 III
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
- Penalty
- Initial $600 · Current $600
Recent events (2)
- · I (S) $600.00
- · Z (S) $600.00
1910.303 F
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
- Penalty
- Current $360
Recent events (1)
- · Q $360.00
1910.303 G01 I
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
1910.303 G02 I
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
1910.304 F04
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
1910.305 G02 III
- Issued
- Mar 4, 2004
- Abate by
- Mar 16, 2004
1910.151 B
- Issued
- Mar 4, 2004
- Abate by
- Mar 9, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.305 B02
- Issued
- Mar 4, 2004
- Abate by
- Mar 9, 2004
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 337122)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 307225649.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.