FAIRMOUNT, IN —
OSHA Inspection: AMERICAN MOBILE POWER DIV. OF AMERICAN GORWOOD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN MOBILE POWER DIV. OF AMERICAN GORWOOD in 619 E JEFFERSON STREET, FAIRMOUNT, IN 46928 (NAICS 336399). OSHA activity number 307291419.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN MOBILE POWER DIV. OF AMERICAN GORWOOD
- Site address
- 619 E JEFFERSON STREET
- City
- FAIRMOUNT
- State
- IN
- ZIP
- 46928
- Mailing
- P O BOX 68, FAIRMOUNT, IN 46928
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- SIC code (legacy)
- 3714
- Employees
- 12
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
12 citations on file for this inspection.
1910.22 D01
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
- Penalty
- Initial $450 · Current $293 Reduced
Recent events (2)
- — I (S) $292.50
- — Z (S) $450.00
1910.23 C01
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.212 A03 II
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
- Penalty
- Initial $600 · Current $390 Reduced
Recent events (2)
- — I (S) $390.00
- — Z (S) $600.00
1910.304 F04
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
- Penalty
- Initial $450 · Current $293 Reduced
Recent events (2)
- — I (S) $292.50
- — Z (S) $450.00
1910.132 D02
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.147 C01
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.178 L01 I
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.178 M05 I
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.242 B
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.303 E
- Issued
- Dec 15, 2004
- Abate by
- Jan 12, 2005
1910.1200 E01
- Issued
- Dec 15, 2004
- Abate by
- Feb 12, 2005
Recent events (2)
- — P (O)
- — Z (O)
1910.1200 H
- Issued
- Dec 15, 2004
- Abate by
- Feb 12, 2005
Recent events (2)
- — P (O)
- — Z (O)
More inspections at American Mobile Power DIV. of American Gorwood
View American Mobile Power DIV. of American Gorwood's full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in IN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307291419.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.