ALEXANDRIA, VA —
OSHA Inspection: HBW GROUP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HBW GROUP, INC. in 1500 W. BRADDOCK ROAD, ALEXANDRIA, VA 22302 (NAICS 236220). OSHA activity number 307354332.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HBW GROUP, INC.
- Site address
- 1500 W. BRADDOCK ROAD
- City
- ALEXANDRIA
- State
- VA
- ZIP
- 22302
- Mailing
- 1055 FIRST STREET, SUITE 200, ROCKVILLE, MD 20850
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1542
- Employees
- 3
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
510001 A
- Issued
- Mar 25, 2004
- Abate by
- Apr 11, 2004
- Penalty
- Initial $1,225 · Current $1,225
General-duty citation text
Title 40.1-51.1.(a), Code of Virginia: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: There was no fixed vertical ladder installed in the 53 1/4" deep pit for safe access as required in pits over 36" deep by ANSI A17.1-1978, Section 106.1d.2, American National Standard for Elevators, Dumbwaiters, and Moving Walks, a nationally recognized consensus document. One feasible and acceptable abatement method, among others, to correct this hazard is to install the proper access ladder. (b)The ground-level access door to the elevator pit was not of a self-closing type and was not provided with a spring-type lock arranged to permit the door to be opened from the inside of the pit without a key as required by ANSI A17.1-1978, Section 106.1d.3, American National Standard for Elevators, Dumbwaiters, and Moving Walks, a nationally recognized consensus document. This resulted in an employee of the building occupant opening the access door from the outside and falling into the pit and receiving serious injuries. "One feasible and acceptable abatement method, among others, to correct this hazard is to install the proper self-closing fire door with a "panic bar" type latching device.g
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1225.00
More inspections at HBW Group, INC.
View HBW Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307354332.