Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUSTIN ELECTRIC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AUSTIN ELECTRIC, INC. in 171ST AND TORRENCE, LANSING, IL 60438 (NAICS 238210). OSHA activity number 307367805.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Austin Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Austin Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
171ST AND TORRENCE
City
LANSING
State
IL
ZIP
60438
Mailing
131 AIRPORT ROAD, JOLIET, IL 60431
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
20
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
May 20, 2004
Abate by
May 25, 2004
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer failed to
provide a place of employment which was free of recognized hazards that
were likely to
cause death or serious harm to employees:
(a) On or about April 26, 2004, at the above address job site, an employee
of LaGrange
Crane operated a crane to lift a Austin Electric employee in a man basket
to an approximate
height of 60-70 feet. The crane was not equipped with a positive acting
device to prevent
contact between the load block or overhaul ball and the boom tip
(anti-two-blocking device),
or by a system to deactivate the hosting action before damage occurs in
the event of a two-
blocking situation (two block damage prevention feature). The employee in
the man basket
was thereby exposed the hazards associated with falls of approximately
60-70 feet.
A feasible means of abatement would be to provide a positive acting device
which prevents
contact between the load block or overhaul ball and boom tip
(anti-two-blocking device), or a
system to deactivate the hositing action before damage occurs in the event
of a two-blocking
situation (two block damage prevention feature) in accordance with the
crane manufacturer's
requirements and ASME/ANSI B30.5 1989.
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

View Austin Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307367805.