SCHILLER PARK, IL ·
OSHA Inspection: AMCO ENGINEERING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMCO ENGINEERING COMPANY in 3801 NORTH ROSE, SCHILLER PARK, IL 60176 (NAICS 332999). OSHA activity number 307494070.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMCO ENGINEERING COMPANY
- Site address
- 3801 NORTH ROSE
- City
- SCHILLER PARK
- State
- IL
- ZIP
- 60176
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- SIC code (legacy)
- 3499
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 18, 2004
- Abate by
- May 4, 2004
- Penalty
- Initial $1,100 · Current $770 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of moving parts of machinery: a) One Grub vertical band saw and Four Haberele cut-off saws were not equipped with a magnetic restart or similar devices, as prescribed by the American National Standards for Metal Cutting Saws, ANSI B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply would prevent the saws from restarting automatically when power is restored. The machines were used during the period between September 16, 2003 and March 16, 2004. Among others, one feasible and acceptable means of abatement would be to provide a magnetic restarter or similar device as required by ANSI B11.10-1990. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $770.00
- · Z (S) $1100.00
1910.147 C06 I
- Issued
- Mar 18, 2004
- Abate by
- Apr 13, 2004
- Penalty
- Initial $1,375 · Current $963 Reduced
Recent events (2)
- · I (S) $962.50
- · Z (S) $1375.00
More inspections at Amco Engineering Company
View Amco Engineering Company's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307494070.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.