DUTCH HARBOR, AK —
OSHA Inspection: GLACIER FISH COMPANY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GLACIER FISH COMPANY LLC in F/V NORTON SOUND, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 307504100.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLACIER FISH COMPANY LLC
- Site address
- F/V NORTON SOUND
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- 1200 WESTLAKE AVE N, SUITE 900, SEATTLE, WA 98109
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311712
- SIC code (legacy)
- 2092
- Employees
- 23
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 17, 2009
- Abate by
- Mar 20, 2009
- Penalty
- Initial $875 · Current $438 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards in the engine room: (a)Glacier Fish Company LLC (F/V Norton Sound) Engine Room: On or about February 1, 2009, an unqualified employee was exposed to an electrical shock hazard due to an unguarded opening in front of the 208/120 Primary Distribution Control Panel which was missing a protective cover between breakers 5 and 6 controlling the 208V breaker panel #4 for the main deck and the 120V breaker panel #5 for the wheelhouse. Among other methods, a feasible means of abatement would include protecting open circuits with a cover as required by NEC article 111.27(A)(2). Abatement certification is required for this item.
Recent events (2)
- — I (S) $437.50
- — Z (S) $875.00
1918.91 A
- Issued
- Feb 17, 2009
- Abate by
- Mar 20, 2009
More inspections at Glacier Fish Company LLC