OSHA Inspection: SHELFORD'S BOAT LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHELFORD'S BOAT LTD in F/V ALEUTIAN LADY, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 307504167.

Watch Shelford'S Boat LTD — free Get an email when a new federal OSHA severe-injury report for Shelford'S Boat LTD is published. One employer, no account, unsubscribe in one click.
Establishment
SHELFORD'S BOAT LTD
Site address
F/V ALEUTIAN LADY
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
PO BOX 12946, MILL CREEK, WA 98082
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311712
SIC code (legacy)
2092
Employees
16
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $750.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to electrical hazards in the engine room:
(a)Shelford's Boat LTD (F/V Aleutian Lady) Passageway and Engineering: On
or about
February 1, 2009, unqualified employees were exposed to electrical shock
hazards due
to unguarded openings exposing energized busbars or controller parts and
inadequate
labeling on:
1. Passage panel: 208V (3) openings 1" x 2 1/4" each. Labeling
inadequate,
2. Shop panel: duct tape over breaker opening. Inadequate
labeling,
3. Engine Room: Lower compressor motor junction 208V (no
covers on box),
4. Engine Room: Port generator area 208V 300 Amp breaker
multiple openings,
5. Engine Room: Harbor generator panels tied into port MCC
panel 4" x 3" opening (1) on inboard and (6) Openings on
outboard panel.
Among other methods, a feasible means of abatement would include
protecting open circuits
with a cover as required by the 2008 NEC article 110.27(A)(2) and legibly
labeling disconnects
within panels as required by the 2008 NEC 110.22(A).
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1910.242 B

Serious Gravity 02 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $300.00 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $600.00

1910.253 B04 III

Serious Gravity 01 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $450.00 · Current $225.00 Reduced
Recent events (2)
  • — I (S) $225.00
  • — Z (S) $450.00

1918.24 A

Serious Gravity 05 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1050.00 · Current $525.00 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $1050.00

1918.33 A

Serious Gravity 02 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $300.00 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $600.00

1918.35

Serious Gravity 05 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1050.00 · Current $525.00 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $1050.00

1918.32 B

Serious Gravity 02 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

View SHELFORD'S BOAT LTD's full OSHA safety record →