VERNON, LA —
OSHA Inspection: K&L CONTRACTORS INC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of K&L CONTRACTORS INC in 3 MI EAST OF LA 155/542 JCT ON S SIDE OF LA 155, VERNON, LA 71227 (NAICS 238910). OSHA activity number 307596643.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- K&L CONTRACTORS INC
- Site address
- 3 MI EAST OF LA 155/542 JCT ON S SIDE OF LA 155
- City
- VERNON
- State
- LA
- ZIP
- 71227
- Mailing
- 1173 CR 1092, CENTER, TX 75935
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- SIC code (legacy)
- 1389
- Employees
- 21
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 12, 2004
- Abate by
- Nov 24, 2004
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of: a) For the period of time up to and including 27 Sep 04, the employer did not always ensure and verify that pressure vessels used within the pumping system were properly manufactured, inspected and capable of operating at required pressures. A compression dampener of non-code origin was used as a baffle to control hose movement during pumping operations, ruptured due to imperfections exceeding standard allowance for defects and the incorrect sized material. This exposed employees to the hazards and injuries related to the sudden and unexpected release of pressure (500-2000psi). According to ASTM A53/A 53M-01, "Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless", Paragraph 14.2, it states that: "Surface imperfections that penetrate more than 12.5of the nominal wall thickness or encroach on the minimum wall thickness shall be considered defects. Pipe with defects shall be given one of the following dispositions: 1.The defect shall be removed by grinding... 2....are permitted to be repaired in accordance with welding procedures of [paragraph] 14.5 [of this standard]. 3.The sections of pipe containing the defect may be cut out..., or 4.Rejected." Pitting seen along the rupture surface show pitting varing in depths between 28.5and 42.8of the nominal wall thickness of the pipe. According to ASTM A53/A 53M-01, "Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless", Table X2.2, it states that the nominal wall thickness for a 6", Sch 80 pipe is .432". Sch 80 pipe was identified on the shop drawing as the type of pipe section used for the construction of the dampener. Thickness measurements at the incident site identified a wall thickness of approx .250" along the entire 11" rupture surface, indicating a Sch 40 pipe. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to: 1.Assure that pressure vessels used in conjunction with the pumping system are manufactured by ASME Pressure Vessel certified manufacturers 2.Perform Non-destructive testing of any pressure vessels used with the pumping system using the requirements set by API Recommended Practice RP510, "Pressure Vessel Inspection Code" or Section V of the ASME Boiler & Pressure Vessel Code. DISCLAIMERS: 1) You are not limited to the abatement methods suggested above. 2) The methods explained are general and may not be effective in all cases. 3) The employer is responsible for selecting and carrying out an appropriate method.iate
Recent events (2)
- — J (S) $1050.00
- — Z (S) $2100.00
More inspections at K&L Contractors INC
View K&L Contractors INC's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307596643.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.