OSHA Inspection: K&L CONTRACTORS INC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of K&L CONTRACTORS INC in 3 MI EAST OF LA 155/542 JCT ON S SIDE OF LA 155, VERNON, LA 71227 (NAICS 238910). OSHA activity number 307596643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K&L Contractors INC — free Get an email when a new federal OSHA severe-injury report for K&L Contractors INC is published. One employer, no account, unsubscribe in one click.
Establishment
K&L CONTRACTORS INC
Site address
3 MI EAST OF LA 155/542 JCT ON S SIDE OF LA 155
City
VERNON
State
LA
ZIP
71227
Mailing
1173 CR 1092, CENTER, TX 75935
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
SIC code (legacy)
1389
Employees
21
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 12, 2004
Abate by
Nov 24, 2004
Penalty
Initial $2,100 · Current $1,050 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees a place of employment which was free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazard of:
a)  For the period of time up to and including 27 Sep 04, the employer did
not always
ensure and  verify that pressure vessels used within the pumping system
were properly
manufactured, inspected and capable of operating at required pressures. A
compression
dampener of non-code origin was used as a baffle to control hose movement
during
pumping operations, ruptured due to imperfections exceeding standard
allowance for
defects and the incorrect sized material. This exposed employees to the
hazards and
injuries related to the sudden and unexpected release of pressure
(500-2000psi).
According to ASTM A53/A 53M-01, "Standard Specification for Pipe, Steel,
Black and
Hot-Dipped, Zinc-Coated, Welded and Seamless", Paragraph 14.2, it states
that:
"Surface imperfections that penetrate more than 12.5of the nominal wall
thickness or
encroach on the minimum wall thickness shall be considered defects. Pipe
with defects
shall be given one of the following dispositions:
1.The defect shall be removed by grinding...
2....are permitted to be repaired in accordance with welding procedures of
[paragraph] 14.5 [of this standard].
3.The sections of pipe containing the defect may be cut out..., or
4.Rejected."
Pitting seen along the rupture surface show pitting varing in depths
between 28.5and
42.8of the nominal wall thickness of the pipe.
According to ASTM A53/A 53M-01, "Standard Specification for Pipe, Steel,
Black and
Hot-Dipped, Zinc-Coated, Welded and Seamless", Table X2.2, it states that
the nominal
wall thickness for a 6", Sch 80 pipe is .432". Sch 80 pipe was identified
on the shop
drawing as the type of pipe section used for the construction of the
dampener. Thickness
measurements at the incident site identified a wall thickness of approx
.250" along the
entire 11" rupture surface, indicating a Sch 40 pipe.
Among other methods, one feasible and acceptable abatement method to
correct this
hazard would be to:
1.Assure that pressure vessels used in conjunction with the pumping system
are
manufactured by ASME Pressure Vessel certified manufacturers
2.Perform Non-destructive testing of any pressure vessels used with the
pumping
system using the requirements set by API Recommended Practice RP510,
"Pressure Vessel Inspection Code" or Section V of the ASME Boiler &
Pressure
Vessel Code.
DISCLAIMERS:
1) You are not limited to the abatement methods suggested above.
2) The methods explained are general and may not be effective in all cases.
3) The employer is responsible for selecting and carrying out an