DURANGO, CO —
OSHA Inspection: DURANGO MARBLE AND GRANITE, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of DURANGO MARBLE AND GRANITE, LLC in 190 SAWYER DR. UNIT C, DURANGO, CO 81303 (NAICS 327991). OSHA activity number 307650945.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DURANGO MARBLE AND GRANITE, LLC
- Site address
- 190 SAWYER DR. UNIT C
- City
- DURANGO
- State
- CO
- ZIP
- 81303
- Mailing
- 462 TURNER DR. #102R, DURANGO, CO 81303
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- SIC code (legacy)
- 3281
- Employees
- 8
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 25, 2006
- Abate by
- Sep 28, 2006
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.133 A01
- Issued
- Sep 25, 2006
- Abate by
- Sep 28, 2006
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.178 L01 II
- Issued
- Sep 25, 2006
- Abate by
- Nov 20, 2006
- Penalty
- Initial $1,050 · Current $420 Reduced
Recent events (2)
- — I (S) $420.00
- — Z (S) $1050.00
1910.242 B
- Issued
- Sep 25, 2006
- Abate by
- Oct 20, 2006
- Penalty
- Initial $525 · Current $210 Reduced
Recent events (2)
- — I (S) $210.00
- — Z (S) $525.00
1910.305 B02
- Issued
- Sep 25, 2006
- Abate by
- Sep 28, 2006
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.334 A05 I
- Issued
- Sep 25, 2006
- Abate by
- Nov 20, 2006
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.1000 C
- Issued
- Sep 25, 2006
- Abate by
- Feb 9, 2007
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.1000 E
- Issued
- Sep 25, 2006
- Abate by
- Feb 9, 2007
9010
Recent events (2)
- — I (S)
- — Z (S)
1910.134 C01
- Issued
- Sep 25, 2006
- Abate by
- Nov 20, 2006
Recent events (2)
- — I (S)
- — Z (S)
1910.134 E01
- Issued
- Sep 25, 2006
- Abate by
- Nov 20, 2006
Recent events (2)
- — I (S)
- — Z (S)
1910.23 E02
- Issued
- Sep 25, 2006
- Abate by
- Sep 28, 2006
- Penalty
- Initial $300 · Current $120 Reduced
Recent events (2)
- — I (O) $120.00
- — Z (O) $300.00
1910.1200 E01
- Issued
- Sep 25, 2006
- Abate by
- Nov 20, 2006
- Penalty
- Initial $300 · Current $120 Reduced
Recent events (2)
- — I (O) $120.00
- — Z (O) $300.00
5(a)(1)
- Issued
- Sep 25, 2006
- Abate by
- Nov 13, 2006
- Penalty
- Initial $1,050 · Current $420 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of exploding shattered plastic: In the granite fabrication area, the employer was transporting above ground compressed air through 3/4 inch regular LCP poly vinyl chloride (PVC) pipes. The PVC pipe was used to supply compressed air throughout the facility. The pipes were primarily overhead and at eye level. These lines also are used to feed air hoses used by employees daily. Among other methods, the following are feasible and acceptable methods to minimize the probability of injury during the transfer of compressed air throughout the facility. 1. Follow American Society for Testing and Materials (ASTM) Standard D1785-86, which states polyvinyl chloride (PVC), pipes can be used for transportation of compressed air and gases only if the PVC pipes made of shatter resistant material or are encased in a shatter resistant material. 2. Follow American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.8-198 Gas Transmission and Distribution Piping Systems Standard, sections 842.32, 842.43 and 849.52(b) which limits the operating pressure of plastic piping distributions systems to 100 pounds per square inch (psi) and prohibits the installation of such systems above ground except where " the above ground portion of the plastic service line is completely enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration." 3. Replace all existing PVC pipes with a type of piping rated to transport compressed air safely above ground. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $420.00
- — Z (S) $1050.00
More inspections at Durango Marble and Granite, LLC
View Durango Marble and Granite, LLC's full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307650945.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.