Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TECHNICAL ERECTORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TECHNICAL ERECTORS, INC. in 106 BOSS ROAD, SYRACUSE, NY 13211 (NAICS 332323). OSHA activity number 307684845.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Technical Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Technical Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
106 BOSS ROAD
City
SYRACUSE
State
NY
ZIP
13211
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
SIC code (legacy)
3446
Employees
18
Ownership type
A

14 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 4 instances 2 exposed
Issued
Aug 9, 2004
Abate by
Aug 12, 2004
Penalty
Initial $500 · Current $300 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer
did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to THE HAZARD OF BEING STRUCK-BY THE LOAD:
a)Paint spray area overhead hoists, on or about 07/09/2004: Two one ton
overhead electric hoists, Serial Numbers unknown had no frequent or
periodic inspections conducted nor records maintained of those inspections.
b)Prefab area overhead motor hoist, on or about 07/09/2004: One 3 ton Twin
City Overhead Electric hoist, serial number unknown had no frequent or
periodic inspections conducted nor records maintained of those inspections.
c)Band Saw area Overhead hoist, on or about 07/09/2004: One 3 ton Twin City
electric overhead hoist, serial number unknown had no frequent or periodic
inspections conducted nor records maintained of those inspections.
d)Fab shop area near overhead shipping/receiving door, on or about
07/09/2004: One 5 ton electric overhead hoist, unknown name and serial
number had no frequent or periodic inspections conducted nor records
maintained of those inspections.
Among other methods, feasible and acceptable abatement methods to correct
this
hazard is to:
1.Conduct frequent and periodic inspections of all hoisting equipment.
2.Maintain dated inspection reports or comparable records on critical items
such as hoisting machinery and other lifting devices in accordance with
ANSI
B30.16-1987, Chapter 16-2.
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $500.00

1910.37 A03

Serious Gravity 03 2 instances 5 exposed
Issued
Aug 9, 2004
Abate by
Aug 12, 2004
Penalty
Initial $625 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $625.00

1910.107 E02

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Aug 12, 2004
Penalty
Initial $625 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $625.00

1910.107 G02

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 K03

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Penalty
Initial $625 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $625.00

1910.134 G01 IA

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 H01

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 H02 I

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Recent events (2)
  • — I (S)
  • — Z (S)

1910.184 E03 I

Serious Gravity 02 3 instances 5 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Penalty
Initial $500 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $500.00

1910.253 E03 IIC3

Serious Gravity 02 3 instances 4 exposed
Issued
Aug 9, 2004
Abate by
Aug 12, 2004
Penalty
Initial $500 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $500.00

1910.253 E03 IIC2

Serious Gravity 02 2 instances 4 exposed
Issued
Aug 9, 2004
Abate by
Aug 12, 2004
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 E01

Repeat Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Penalty
Initial $5,000 · Current $3,000 Reduced
Recent events (2)
  • — I (R) $3000.00
  • — Z (R) $5000.00

1910.134 F02

Repeat Gravity 03 1 instance 1 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Recent events (2)
  • — I (R)
  • — Z (R)

1910.178 A06

Other-than-serious Gravity 01 2 instances 2 exposed
Issued
Aug 9, 2004
Abate by
Sep 11, 2004
Recent events (2)
  • — I (O)
  • — Z (O)

View Technical Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307684845.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.