Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WATERTOWN AUTO SALES INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WATERTOWN AUTO SALES INC in 18890 US ROUTE 11, WATERTOWN, NY 13601 (NAICS 441120). OSHA activity number 307688127.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Watertown Auto Sales INC for free Get an email when a new federal OSHA severe-injury report for Watertown Auto Sales INC is published. One employer, no account, unsubscribe in one click.
Site address
18890 US ROUTE 11
City
WATERTOWN
State
NY
ZIP
13601
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441120
SIC code (legacy)
5521
Employees
15
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 8, 2005
Abate by
Mar 14, 2005
Penalty
Initial $1,500 · Current $975 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a crushing hazard created by the sudden and unpredictable
descent of a vehicle
elevated by an automotive lift:
a)In the Service Area, on or about 12/17/04:  Ammco, two post automotive
lift,
model number AL-7, serial number P000006651 was missing the locking
device for the left front swing arm.
b)Anchor bolts on the Ammco two post lift, serial number P000006651, were
not re-torqued to one hundred fifty foot pounds on an monthly basis as
required by the lift manufacturer.
c)The hydraulic pump on the Ammco two post lift, serial number P000006651,
was leaking around the top seal.
d)The employer did not train and document employees were instructed in the
safe use and operation of automotive lifts.
Among other methods, several feasible and acceptable abatement methods to
correct
these hazards are to:
1.Install locking device for the front swing arm.
2.Establish a periodic inspection as recommended by the manufacturer,
to include re-torquing of the anchor bolts and repairing all leaks, to
ensure the safe operation of the lift.
3.Document that all employees have received training in the safe use and
operation of automotive lifts.
Abatement certification must be submitted for this items.ted
Recent events (2)
  • · I (S) $975.00
  • · Z (S) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307688127.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.