LAWRENCEVILLE, GA ·
OSHA Inspection: FORESTER ROLLER CO.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of FORESTER ROLLER CO. in 277 INDUSTRIAL PARK DRIVE, LAWRENCEVILLE, GA 30245 (NAICS 326299). OSHA activity number 307835470.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FORESTER ROLLER CO.
- Site address
- 277 INDUSTRIAL PARK DRIVE
- City
- LAWRENCEVILLE
- State
- GA
- ZIP
- 30245
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- SIC code (legacy)
- 3069
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 9, 2005
- Abate by
- Jun 22, 2005
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: fires and explosion due to the over heating of rubber(s) products that were the result of processing which generated combustible particulate solids which were conveyed to an inadequately maintained and operated dust collection system. (a) Forester Roller Co. Inc., 277 industrial Park Drive, Lawrenceville, Georgia. Employees were exposed to the hazards of fire and explosion where combustible particulate solids (rubber dust) was being over heated during the process of grinding the rubber covering of rollers and there was no prevention/suppression system to prevent a fire and/or explosion from occurring at or inside the ductwork or dust collection system. Among other methods, one feasible and acceptable abatement method to correct this hazard is to: apply the explosion prevention technical design requirements of NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids, and/or NFPA 69 Standard on Explosion Prevention Systems, and/or NFPA 68 Guide for Venting Deflagrations, to systems and facilities and equipment that handle combustible particulate solids based upon consideration of the physical and chemical properties and hazardous characteristics that define the materials being processed. ABATEMENT VERIFICATION AND DOCUMENTATION REQUIRED
1910.157 G02
- Issued
- Feb 9, 2005
- Abate by
- Mar 15, 2005
- Penalty
- Initial $450 · Current $450
More inspections in this industry (NAICS 326299)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307835470.