KNIGHTDALE, NC ·
OSHA Inspection: RUEBEN BROADWELL
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RUEBEN BROADWELL in 3621 SMITHFIELD RD., KNIGHTDALE, NC 27545 (NAICS 111910). OSHA activity number 307904003.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUEBEN BROADWELL
- Site address
- 3621 SMITHFIELD RD.
- City
- KNIGHTDALE
- State
- NC
- ZIP
- 27545
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
- Migrant workforce
- X
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 111910
- SIC code (legacy)
- 0132
- Employees
- 16
- Ownership type
- A
Citations
4 citations on file for this inspection.
95012901
- Issued
- Feb 25, 2005
- Abate by
- Mar 3, 2005
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees living in the wood framed house at the end of the dirt path were exposed to electrical hazards from improper use of temporary wiring, exposure to live electrical parts, and lack of permanent and continuous path to ground from circuits, equipment,and enclosures. a) The refrigerator in the living room was not grounded or GFCI protected. b) Ceiling light fixture in the kitchen consisted of a light bulb in a socket with two wires improperly spliced to the two wires hanging from the ceiling. c) The outlet next to the toilet in the bathroom was not grounded and was missing a cover plate. d) Outlet in kitchen next to refrigerator was missing cover plate. e) Temporary wiring was being used on a permanent basis throughout this house. This temporary wiring was attached to walls and running through doorways and windows inside and outside the dwelling. In one case, a window air conditioning unit was plugged into a drop cord that was attached to the house along the side and to the rear of the house, where it was plugged into an outlet box on the back porch. f) In the back left bedroom, a ceiling fan had been jury- rigged from the blades and motor of what once was a box fan. It was connected via spliced lamp cord to a switch that was not mounted, but dangling from the wire. g) The circuit breaker panel on the back porch had wires running through it that were not protected from abrasion. The outlets on the back porch were not covered. The circuit breaker panel was not labeled and did not have a three foot clearance as a working space. Flammable containers and tools were being stored in front of circuit breaker panel. A spliced fan cord from a window fan, sitting on the ledge of the kitchen window, was plugged into one of the outlets on the back porch. Among others, one feasible and acceptable method of abating this violation is to eliminate all temporary wiring being used on a permanent basis and have permanent wiring installed throughout camp that meets NEC and local building code requirements.
Recent events (2)
- · I (S) $1000.00
- · Z (S) $1000.00
950225 D
- Issued
- Feb 25, 2005
- Abate by
- Mar 3, 2005
- Penalty
- Initial $500
Recent events (2)
- · I (S)
- · Z (S) $500.00
1910.142 C01
- Issued
- Feb 25, 2005
- Abate by
- Mar 3, 2005
950226 A
- Issued
- Feb 25, 2005
- Abate by
- Mar 3, 2005
- Penalty
- Initial $1,000 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $1000.00
More inspections in this industry (NAICS 111910)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307904003.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.