On , OSHA opened a complaint safety inspection of STONE CANYON MASONRY, LLC in BARTON PLACE CONDOMINIUMS, RALEIGH, NC 27603 (NAICS 238140). OSHA activity number 307906149.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stone Canyon Masonry, LLC for free Get an email when a new federal OSHA severe-injury report for Stone Canyon Masonry, LLC is published. One employer, no account, unsubscribe in one click.
Site address
BARTON PLACE CONDOMINIUMS
City
RALEIGH
State
NC
ZIP
27603
Mailing
860 PARK AVE., YOUNGSVILLE, NC 27596
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
SIC code (legacy)
1741
Employees
27
Ownership type
A
Industry flags
Construction safety.

6 citations on file for this inspection.

95012901

Serious 4 instances 5 exposed
Issued
Oct 11, 2004
Abate by
Nov 5, 2004
Penalty
Initial $700 · Current $455 Reduced
North Carolina General Statute 95-129(1) of the Occupational
Safety and Health Act of North Carolina: The employer did not
furnish each of his employees conditions of employment and a
place of employment free from recognized hazards that were
causing or likely to cause death or serious physical harm to
employees in that employees were exposed to falls:
a)site - employees were exposed to unprotected fall
hazards when utilizing orange heavy duty electrical
extension cord and green flexible cable, Genesis,
#50502X4PR24CAT5e+ 2X/8AWG as guys, ties and bracing
for tubular welded frame scaffolds extended to a height
of approximately 28 feet above the lower ground level
when installing brick veneer on the exterior face of a
condominium building.
One feasible and acceptable abatement method, among
others, to correct this hazard is to install and
utilize appropriately designed and manufactured guys,
ties and/or braces in accordance with the
manufacturers requirements and/or recommendations.
or in the Alternative:
29CFR 1926.451(a)(1)
Recent events (2)
  • · I (S) $455.00
  • · Z (S) $700.00

1926.451 G04 I

Serious 1 instance 4 exposed
Issued
Oct 11, 2004
Abate by
Nov 5, 2004
Penalty
Initial $700
Recent events (2)
  • · I (S)
  • · Z (S) $700.00

1926.451 H02 I

Serious 1 instance 2 exposed
Issued
Oct 11, 2004
Abate by
Nov 5, 2004
Recent events (2)
  • · I (S)
  • · Z (S)

1926.451 H02 II

Serious 1 instance 2 exposed
Issued
Oct 11, 2004
Abate by
Nov 5, 2004
Recent events (2)
  • · I (S)
  • · Z (S)

1926.454 A

Serious 3 instances 4 exposed
Issued
Oct 11, 2004
Abate by
Nov 5, 2004
Recent events (2)
  • · I (S)
  • · Z (S)

1926.102 A01

Serious 1 instance 1 exposed
Issued
Oct 11, 2004
Abate by
Nov 5, 2004
Penalty
Initial $250 · Current $165 Reduced