Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VYCOM INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VYCOM INC. in 801 E. COREY STREET, MOOSIC, PA 18507 (NAICS 326113). OSHA activity number 307912295.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vycom INC. — free Get an email when a new federal OSHA severe-injury report for Vycom INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VYCOM INC.
Site address
801 E. COREY STREET
City
MOOSIC
State
PA
ZIP
18507
Mailing
801 E. COREY STREET, MOOSIC, PA 18507
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326113
SIC code (legacy)
3081
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.252 A02 XV

Serious Gravity 03 1 instance 3 exposed
Issued
Jan 24, 2005
Abate by
Mar 11, 2005
Penalty
Initial $2,125 · Current $1,595 Reduced
Recent events (2)
  • — I (S) $1595.00
  • — Z (S) $2125.00

1910.252 B03

Serious Gravity 03 1 instance 1 exposed
Issued
Jan 24, 2005
Abate by
Mar 11, 2005
Penalty
Initial $2,125 · Current $1,595 Reduced
Recent events (2)
  • — I (S) $1595.00
  • — Z (S) $2125.00

1910.252 A02 IIIB

Deleted Serious Gravity 03 1 instance 1 exposed
Issued
Jan 24, 2005
Abate by
Mar 11, 2005
Penalty
Initial $2,125 · Current $2,125
Recent events (2)
  • — I (S) $2125.00
  • — Z (S) $2125.00

1910.22 A01

Serious Gravity 03 1 instance 4 exposed
Issued
Jan 24, 2005
Abate by
Mar 11, 2005
Penalty
Initial $2,125 · Current $1,595 Reduced
Recent events (2)
  • — I (S) $1595.00
  • — Z (S) $2125.00

5(a)(1)

Serious Gravity 03 2 instances 10 exposed
Issued
Jan 24, 2005
Abate by
Sep 30, 2005
Penalty
Initial $2,125 · Current $1,595 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to severe burn injuries from a dust explosion
hazard that could have
resulted from, or been exacerbated by, the propagation of a fire or
explosion in the duct
work that was not equipped with isolation devices and the dust collection
systems that were
located inside of the building structure.
a) Building #4, Dry Blend: The dust collection systems for Tower #1 and
Tower #2
were located inside of the building, on or about October 5, 2004.
b) Building #4, Dry Blend: Duct work connecting pieces of equipment were
not
equipped with isolation devices, on or about October 5, 2004.
"AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHOD TO CORRECT THESE HAZARDS IS TO RELOCATE THE DUST
COLLECTION SYSTEMS TO AN OUTSIDE AREA PER NFPA 654, SECTION 3.13.1.1
AND TO INSTALL ISOLATION DEVICES IN THE DUCT WORK PER NFPA 654,
SECTION 3.13.1.5."
ABATEMENT CERTIFICATION REQUIREDATION
Recent events (3)
  • — P (S) $1595.00
  • — I (S) $1595.00
  • — Z (S) $2125.00

View Vycom INC.'s full OSHA safety record →