RIO PIEDRAS, PR ·
OSHA Inspection: ASEM DE PUERTO RICO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ASEM DE PUERTO RICO in CARR. 22, BO. MONACILLOS, RIO PIEDRAS, PR 00935 (NAICS 622110). OSHA activity number 307934950.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASEM DE PUERTO RICO
- Site address
- CARR. 22, BO. MONACILLOS
- City
- RIO PIEDRAS
- State
- PR
- ZIP
- 00935
- Mailing
- P.O. BOX 2129, SAN JUAN, PR 00922
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- SIC code (legacy)
- 8062
- Employees
- 1454
- Ownership type
- State government (C)
Citations
7 citations on file for this inspection.
6A0001
- Issued
- Sep 13, 2007
- Abate by
- Nov 15, 2007
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: ASEM of Puerto Rico, Central Kitchen, Centro Medico: While the employees performed cooking works, such as food preparation, it were observed exposed hot water pipes with leaks in its joints and closing valves without protection. Hazard: Contact with hot parts. Among other methods, a feasible and acceptable method correct this hazard is, insulated or cover with a heat resistive material these pipes. ASEM De Puerto Rico, Cocina Central, Centro Medico: Mientras los empleados realizaban trabajos de cocina, tal como preparacion de alimentos, fueron observadas tuberias de agua caliente expuestas con escapes en las juntas y en las valvulas de cierre sin proteccion. Riesgo: Contacto con partes calientes. Entre otros metodos, uno factible y aceptable para corregir este riesgo es, aislar o cubrir con material resistente al calor estas tuberias.e
Recent events (2)
- · I (S) $1487.50
- · Z (S) $2975.00
6A0001
- Issued
- Sep 13, 2007
- Abate by
- Oct 31, 2007
- Penalty
- Initial $1,275 · Current $638 Reduced
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: ASEM of Puerto Rico, Central Kitchen, Centro Medico: While the employees performed cooking works, such as food preparation, it were observed some burners without the gas regulating buttons the gas stove trademark Vulcan, property number 45720. Hazard: Difficult to regulate and/or shut off gas flow Among other methods, a feasible and acceptable method to correct this hazard is, provide at the burners and place regulator buttons that did not have it. ASEM de Puerto Rico, Cocina central, Centro Medico: Mientras los empleados realizaban trabajos de cocina, tal ocmo preparacion de alimentos, fueron observados varios quemadores sin los botones reguladores de flujo de gas en la estufa de gas marca Vulcan, numero de propiedad 45720. Riesgo: Dificultad para regular y/o apagar el flujo de gas. Entre otros metodos uno factible y aceptable para corregir este riesgo es, proveer y colocar los botones reguladores de flujo en los quemadores que no lo tienen.res
Recent events (2)
- · I (S) $637.50
- · Z (S) $1275.00
6A0001
- Issued
- Sep 13, 2007
- Abate by
- Oct 31, 2007
- Penalty
- Initial $1,275 · Current $638 Reduced
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: ASEM of Puerto Rico, Central Kitchen, Centro Medico: While the employees were mixing food, the industrial blender trademark Hamilton Beach, model number 990, serial number 4230B00033, property number 01-45-113, use to this purpose, did not have the locks to maintain the blender cover in place. Hazard: Contact with hot superfaces. Among other methods, a feasible and acceptable method to correct this hazard is, the repair or replacement of this locks ASEM de Puerto Rico, Cocina Central, Centro Medico: Mientras los empleados mezclaban comida, la mezcladora (licuadora) industrial marca Hamilton Beach, modelo num. 990, serie num. 4230B00033, numero de propiedad 01-45-113, usada para este proposito, no tenia los seguros para mantener la tapa de la mezcladora en su lugar. Riesgo: Contacto con superficies calientes. Entre otros metodos, uno factible y aceptalbe para corregir este riesgo es, reparar o reemplazar estos seguros.ar
Recent events (2)
- · I (S) $637.50
- · Z (S) $1275.00
6A0001
- Issued
- Sep 13, 2007
- Abate by
- Nov 15, 2007
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: ASEM of Puerto Rico, Central Kitchen, Centro Medico: One of the aluminum section of the freezer floor trademark Witt-Scott, AL, model no. SA36-1458-A, serial no. E07C37581602002, was observed bent upward. Employee walked to this area to seek food to them cook it. Hazard: Stumbles and/or Falls. Among other methods, a feasible and acceptable method to correct this hazard is, to change the aluminum section bent by a flat one. ASEM de Puerto Rico, Cocina Central, Centro Medico: Una seccion de aluminio del piso del congelador marca Witt-Scott AL, modelo num. SA36-1258-A, serie num. E07C37581602002, fue observada doblada hacia arriba. Empleados caminaban a esta area para buscar alimentos que iban a ser cocinados. Riesgo: Tropezones y/o caidas. Entre otros metodos, uno factible y aceptable para corregir este riesgo es, cambiar la seccion doblada por una lisa.da
Recent events (2)
- · I (S) $850.00
- · Z (S) $1700.00
6A0001
- Issued
- Sep 13, 2007
- Abate by
- Oct 10, 2007
- Penalty
- Initial $1,275 · Current $638 Reduced
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: ASEM of Puerto Rico, Central Kitchen, Centro Medico: While the employees performed cooking works, such as food preparation, it was observed an air extractor, without other identification that did not operate. Hazard: Smoke Inhalation; Among other methots, a feasible and acceptable method to correct this hazard is, to repair or replace this air extractor. ASEM de Puerto Rico, Cocina Central, Centro Medico: Mientras los empleados realizaban trabajos de cocina tal como preparacion de alimentos, fue observado un extractor de aire, sin otra identificacion, que no operaba. Riesgo: Inhalacion de humo. Entre otros metodos, uno factible y aceptable para corregir este riesgo es, reparar o reemplazar este extractor de aire.ctor
Recent events (2)
- · I (S) $637.50
- · Z (S) $1275.00
1910.22 A02
- Issued
- Sep 13, 2007
- Abate by
- Oct 31, 2007
- Penalty
- Initial $2,975 · Current $1,488 Reduced
Recent events (2)
- · I (S) $1487.50
- · Z (S) $2975.00
1910.157 C04
- Issued
- Sep 13, 2007
- Abate by
- Sep 18, 2007
- Penalty
- Initial $1,275 · Current $638 Reduced
Recent events (2)
- · I (S) $637.50
- · Z (S) $1275.00
More inspections in this industry (NAICS 622110)