AUSTIN, TX —
OSHA Inspection: A-CLEAR VIEW
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of A-CLEAR VIEW in 811 BARTON SPRINGS ROAD, AUSTIN, TX 78704 (NAICS 561720). OSHA activity number 307955724.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A-CLEAR VIEW
- Site address
- 811 BARTON SPRINGS ROAD
- City
- AUSTIN
- State
- TX
- ZIP
- 78704
- Mailing
- P.O. BOX 767, GEORGETOWN, TX 78627
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- SIC code (legacy)
- 7349
- Employees
- 2
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 11, 2006
- Abate by
- Jan 18, 2006
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of falling 78 - 117 feet, i.e. 78 feet (23.7 meters) from the roof deck to the third floor roof or 117 feet (35.6 meters) to the ground: (a) On or about October 17, 2005, employee(s) were exposed to the hazards of falling 78 - 117 feet from the roof of the building located at 811 Barton Springs Road in Austin, Texas while performing window washer helper tasks including pushing a portable rooftop roller along the parapet wall, moving supplies and equipment such as tether ropes, and leaning over the approximately 20 inch high parapet wall to talk to the Window Washer seated in the Sky Genie Seatboard System. Deficiencies in the employer's work safety and fall protection plan resulted in the Helper falling 6 stories from the roof deck to the 3rd floor roof, including, but not limited to: failure to ensure that suspended work was not performed unless it was determined that the building had provided, identified and certified anchorages complying with Section 9 or 10 of ANSI/IWCA I-14.1-2001 for: independent safety lines; tie-backs for outriggers, parapet clamps and cornice hooks; primary support anchorages for powered and manual boatswain's chairs; primary support anchorages for rope descent systems; horizontal (rope) lines or lifelines; and wherever else required; failure to require the use of personal fall arrest equipment when approaching within 6 feet (1.8 meters) of an unguarded roof edge; and failure to supervise employees. Among other methods, a feasible and acceptable abatement method to correct these hazards is as follows: 1) Prior to commencing suspended work, inspect the surface for structural anchorage points that are capable of supporting the intended loads in accordance with ANSI/IWCA I-14.1-2002; instruct employees in the proper use of these anchorages and all equipment provided them; and supervise the use of the equipment and devices to ensure that safe working practices are observed. (b) On or about October 17, 2005, employee(s) were exposed to the hazards of falling 78 - 117 feet from a suspended seatboard system while cleaning windows on the building located at 811 Barton Springs Road in Austin, Texas with the Window Washer's life line connected to the suspension device for the rope descent system instead of an independent anchor point. Both the primary support line for the descent control system and employee life line were attached to the back end of the Suspended Solutions Rooftop Roller, and a single tie-back rope was used to tether the rooftop roller to a roof hatch. The practice of attaching both the utility (main) line and the employee life line of a window washer's descent control system to the same anchor point exposes employees to the hazards of a fall since a single failure of the device could cause a worker to fall. Among other methods, a feasible and acceptable abatement method to correct these hazards is as follows: 1) Use of a separate fall arrest system [including sit harness or full body harness; rope grab or similar device; lifeline; and anchorage (all of which are completely independent of the friction device and its support system)], so that any failure in a friction device, support seat (or harness), support line, or anchorage system will not affect the ability of the fall arrest system to operate and quickly stop the employee's fall. Use of a horizontal line attached securely to substantial members of the building structure could serve as a separate and independent anchor point for the employee life line.
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
More inspections in this industry (NAICS 561720)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307955724.