JOPLIN, MO —
OSHA Inspection: PROTEIN SOLUTIONS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PROTEIN SOLUTIONS, LLC in 3800 E 32ND STREET, JOPLIN, MO 64804 (NAICS 311119). OSHA activity number 308097468.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROTEIN SOLUTIONS, LLC
- Site address
- 3800 E 32ND STREET
- City
- JOPLIN
- State
- MO
- ZIP
- 64804
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311119
- SIC code (legacy)
- 2048
- Employees
- 46
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- May 12, 2006
- Abate by
- Jun 8, 2006
- Penalty
- Initial $1,750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of ammonia exposures due to the unsafe design and operation of refrigeration systems: At 3800 E 32nd St, Joplin, MO - the ammonia refrigeration system did not meet the applicable requirements for the safe design, construction, installation, and operation of refrigeration systems in that: (a)The refrigerating machinery room door opening into the building did not open outward and was not self-closing. (b)The refrigerating machinery room did not contain an operating detector, located in an area where refrigerant from a leak could concentrate, that would actuate an alarm and mechanical ventilation. While ultimate responsibility for correcting the hazards rests with the employer, given his/her superior knowledge of the workplace, feasible and acceptable methods to correct these hazards, among others, include: (1)Install the door to the mechanical room so that it opens outwards and is self- closing as prescribed by Section 8.11.2 of ANSI/ASHRAE 15-2001, Safety Standard for Refrigeration Systems. (2)Install an alarm system in the machinery room that complies with Section 8.11.2.1 of the ANSI/ASHRAE 15-2001, Safety Standard for Refrigeration Systems. Abatement Note: Abatement certification is required for this item - use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.T
Recent events (2)
- — F (S)
- — Z (S) $1750.00
1910.120 Q01
- Issued
- May 12, 2006
- Abate by
- Jun 8, 2006
- Penalty
- Initial $1,750 · Current $1,750
Recent events (2)
- — F (O) $1750.00
- — Z (S) $1750.00
1910.120 Q06
- Issued
- May 12, 2006
- Abate by
- Jun 8, 2006
Recent events (2)
- — F (O)
- — Z (S)
1910.134 C01
- Issued
- May 12, 2006
- Abate by
- Jun 8, 2006
- Penalty
- Initial $1,750
Recent events (2)
- — F (O)
- — Z (S) $1750.00
1910.134 D01 III
- Issued
- May 12, 2006
- Abate by
- Jun 5, 2006
Recent events (2)
- — F (O)
- — Z (S)
1910.147 C04 I
- Issued
- May 12, 2006
- Abate by
- Jun 8, 2006
- Penalty
- Initial $1,750 · Current $875 Reduced
Recent events (2)
- — F (S) $875.00
- — Z (S) $1750.00
More inspections in this industry (NAICS 311119)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308097468.