VILLA PARK, IL —
OSHA Inspection: ACME SCALE SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ACME SCALE SYSTEMS, INC. in 1100 N. VILLA AVE., VILLA PARK, IL 60181 (NAICS 423440). OSHA activity number 308151414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME SCALE SYSTEMS, INC.
- Site address
- 1100 N. VILLA AVE.
- City
- VILLA PARK
- State
- IL
- ZIP
- 60181
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423440
- SIC code (legacy)
- 5046
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 20, 2006
- Abate by
- Apr 6, 2006
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment or a place of employment which were free of recognized hazards that likely to cause serious physical harm or death in that the employees were exposed to hoist collapse or falling equipment. Among Feasible Abatement Method is to comply with the ANSI Standards for Underhung Hoist ANSI B30.16-1993, such as but not limited to the following: 1. Provide frequent and periodic inspections of hoist and its accessories. 2. Qualify the I-beam, the load bearing part of the hoist and other linkages. Mark the beam with the rated load capacity. At the Shop - A heavy Capacity Test Truck was used to test weight scales at customer location. The hoist installed inside the truck was lifting approximately 2000 lbs load at any given time. The total lifted weights were 20,000 lbs. The hoist was not inspected regularly and frequently. The I-beam was not qualified nor marked with the rated load capacity. Abatement certification is required for this item in accordance with the requirement of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
5(a)(1)
- Issued
- Jan 20, 2006
- Abate by
- Apr 6, 2006
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to being struck by a falling load lifted by the custom made lifting device: Custom made spreader bar was used at the customer's location to lift sets of weights from the truck to the weight scale and back to the truck. Feasible and acceptable abatement methods include, but are not necessarily limited to: Comply with ANSI B30.20 - Below the Hook Lifting Devices and: 1. Provide the rated load on the custom made lifting device: 2. Design the lifting device to withstand the forces imposed by its rated load with a minimum design factor of 3. 3. Provide initial, frequent, and periodic inspections of the lifting devices. 4. Ensure that initial proof testing of 125of the rated load was conducted. A heavy Capacity Test Truck was used to test weighing scales at the customer locations. The hoist was installed inside the truck to unload and load 4 - 500 lbs weights using a spreader bar as a lifting device. The bar was not qualified nor marked with the rated load capacity. One of the hooks attached to the bar had a broken tip. Abatement certification is required for this item in accordance with the requirement of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
1910.23 D01 II
- Issued
- Jan 20, 2006
- Abate by
- Feb 22, 2006
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
1910.147 C01
- Issued
- Jan 20, 2006
- Abate by
- Feb 22, 2006
- Penalty
- Initial $300 · Current $150 Reduced
Recent events (2)
- — I (O) $150.00
- — Z (O) $300.00
More inspections at Acme Scale Systems, INC.
View Acme Scale Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423440)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308151414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.