NAPERVILLE, IL —
OSHA Inspection: DUPAGE PRECISION PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DUPAGE PRECISION PRODUCTS in 433 W. SPRING STREET, NAPERVILLE, IL 60540 (NAICS 332710). OSHA activity number 308153253.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUPAGE PRECISION PRODUCTS
- Site address
- 433 W. SPRING STREET
- City
- NAPERVILLE
- State
- IL
- ZIP
- 60540
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- SIC code (legacy)
- 3499
- Employees
- 58
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 21, 2005
- Abate by
- Nov 23, 2005
- Penalty
- Initial $1,400 · Current $700 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish a place of employment which was free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were not protected from automatic restart of metal-cutting saws: The Do All Vertical band saw and the Kalamazoo horizontal band saw did not have magnetic restart provisions. ANSI B11.10-1990, Section 5.2.3.4 states that in the event of an interruption in the electrical power supply, the machine shall not restart automatically when power is restored. A feasible means of abatement would be to provide a magnetic restarter or similar device as required by ANSI B11.10-1990. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $700.00
- — Z (S) $1400.00
1910.213 B03
- Issued
- Sep 21, 2005
- Abate by
- Nov 23, 2005
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C04 II
- Issued
- Sep 21, 2005
- Abate by
- Dec 23, 2005
Recent events (2)
- — I (O)
- — Z (O)
1910.147 C06 I
- Issued
- Sep 21, 2005
- Abate by
- Dec 23, 2005
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Dupage Precision Products
View Dupage Precision Products's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308153253.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.