SAN SEBASTIAN, PR —
OSHA Inspection: FG AUTO CORP DBA AUTOLAND
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FG AUTO CORP DBA AUTOLAND in AVE EMERITO ESTRADA RIVERA 1970, SAN SEBASTIAN, PR 00685 (NAICS 441110). OSHA activity number 308164920.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FG AUTO CORP DBA AUTOLAND
- Site address
- AVE EMERITO ESTRADA RIVERA 1970
- City
- SAN SEBASTIAN
- State
- PR
- ZIP
- 00685
- Mailing
- PO BOX 3870, MAYAGUEZ, PR 00681
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- SIC code (legacy)
- 5511
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
6A0001
- Issued
- Apr 25, 2007
- Abate by
- May 18, 2007
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
7.Establecer un record de reparaciones por escrito. 8.Disponibilidad de los manuales del manufacturero."d Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: a)At Nissan workshop of FG Auto Corp. - The following hydraulic systems Rotary Lift Model, SPO A10N 10000 lbs.; TL Tecno Lifts by AMC; Norco Model, 86000/6000 lbs., which one were used by the employees to lift the vehicule and repair then, were not comply with the requirements establish in the ANSI/ALI- 2000: 1.Leak of operator training about the systems use and operation. 2.A daily inspection were not perform about the following points: a.Accessibility of operating procedures and safety tips. b.Accessibility of the warning labels. c.Accessibility of the rated load capacity of the lift. d.Verify the proper operation of the lifts controls and restraints. e.Verify deformation or excessive wear of other components such as electrical wires, drive chains, cables or screw. f.Verify damage or excessive wear on any of the lift contact points wich engage the vehicle during lifts. g.Verify evidence of hydraulic or pneumatic leaks. 3.The employer did not establish a procedure of periodics inspeccion according the manufacturer manual. 4.A inspection record and findings with all points recomended by the manufacturer and repairs perform did not establish. 5.A qualified inspection according the manufacturer recomendations or at least annually did not perform. 6.A maintenance periodic preventive written record with the manufacturer recomendations that included the repairs and adjustments were not establish. 7.A repairs written record with the manufacturer recomendations were not establish. 8.The manufacturer manuals were not accesible. Hazard: malfunction of the hydraulics systems and mechanicals fails. Among other correction methods some feasible correction method and acceptable are the followings: 1.Trained the employees about the use and operation of the systems. 2.Perform daily inspections about the followings points: a.Accessibility of the operation procedure and general information. b.Accessibility and readability of the safety warning labels. c.Readability of the rated load capacity of the lift. d.Verify the proper operation of the lifts controls and restaints. e.Verify the deformation or excessive wear of the other components such as electrical wires, drive chains, cables or screws. f.Verify the evidence of damage or excessive wear on any of the lift contact points which engage the vehicle during lifting. g.Verify evidence of hydraulic or pneumatic leaks. h.Verify evidence of cracks or loose concrete around floor anchor bolts. 3.Establish a periodic inspection procedure in accordance with the recommendations of the manufacturer. 4.Establish a inspection record and findings with all points recommended by the manufacturer and repairs perform. 5.Perform a qualified inspection according the manufacturer recomendations or at least annually.6.Establish a maintenance periodic preventive written record with the manufacturer recommendations that included the repairs and adjustments. 7.Establish a repairs written record with the manufacturer recommendations. 8.Accessibility of the manufacturer manuals. a)En el taller Nissan de FG Auto Corp. - Los siguientes sistemas hidraulicos modelo Rotary Lift, SPO A10N, 10000 lbs.; TL Tecno Lifts by AMC; modelo Norco, 86000/6000 lbs., eran utilizados por los empleados para levantar y reparar los autos, no cumplian con los siguientes requisitos establecidos en el ANSI/ALI- 2000: 1.Falta de adiestramiento del operador en el uso y operacion de los sistemas. 2.No se realizaron inspecciones diarias sobre los siguientes puntos: a.Acceso a los procedimientos de operacion e informacion general de seguridad. b.Acceso a las etiquetas de aviso. c.Legibilidad de la capacidad de carga del pino. d.Verificar la operacion apropiada de los controles del pino y restricciones. e.Verificar evidencia de deformacion o desgaste excesivo de componentes como lo son la cableria electrica, cadenas, cadenas, cables y/o tornillos. f.Verificar evidencia de dano o desgaste excesivo de cualquier punto de contacto que pudiera estar ocupado mientras un vehiculo es levantado. g.Verificar evidencia de liqueos hidraulicos o neumaticos. h.Verificar evidencia de grietas en el concreto alrededor de los puntos de anclaje. 3.El patrono no establecio un procedimiento de inspecciones periodicas segun el manual del manufacturero. 4.No existia un record de inspeccion con las observaciones y hallazgos de todos los puntos de inspeccion recomendados por el manufacturero y las reparaciones realizadas. 5.No se realizaron inspecciones cualificadas segun las recomendaciones del manufacturero o por lo menos 1 vez al ano. 6.No se establecio un record de mantenimiento periodico preventivo por escrito de acuerdo con las recomendaciones de manufacturero que incluyera las partes reparadas y ajustadas. 7. No se establecio un record de reparaciones por escrito de acuerdo con las recomendaciones del manufacturero. 8.Los manuales de los manufactureros no estaban disponibles. Riesgo: mal funcionamiento de los sistemas hidraulicos y fallas mecanicas. Entre otros medios de correccion varios metodos de correccion factible y aceptable se encuentran los siguientes: 1.Adiestrar a los operadores en el uso y operacion de los sistemas. 2.Realizar inspecciones diarias sobre los siguientes puntos: a.Que los procedimientos de operacion e informacion general de seguridad este accesible. b.Que las etiquetas de aviso esten accesibles y legibles. c.Que la capacidad de carga del pino este legible. d.Verificar la operacion apropiada de los controles del pino y restricciones. e.Verificar la evidencia de deformacion o desgaste excesivo de otros componentes como los son la cableria electrica, cadenas, cables y/o tornillos. f.Verificar la evidencia de dano o desgaste excesivo de cualquier pinto de contacto que pueda estar ocupado mientras el vehiculo es levantado. g.Verificar la evidencia de liqueos hidraulicos y neumaticos. h.Verificar que no haya grietas en el concreto alrededor de os puntos de anclaje. 3.Establecer un procedimiento de inspecciones periodicas preventivos segun el manual del manufacturero. 4.Establecer un record de inspeccion con todas las observaciones y hallazgos de todos los puntos de inspeccion recomendados por el manufacturero y las reparaciones realizadas. 5.Realizar una inspeccion cualificada, segun las recomendaciones del manufacturero o por lo menos una vez al ano. 6.Establecer un record de mantenimiento periodico preventivo por escrito de acuerdo con las recomendaciones del manufacturero.
1910.132 D01
- Issued
- Apr 25, 2007
- Abate by
- May 8, 2007
- Penalty
- Initial $750 · Current $750
1910.132 F01
- Issued
- Apr 25, 2007
- Abate by
- May 8, 2007
- Penalty
- Initial $750 · Current $750
1910.133 A01
- Issued
- Apr 25, 2007
- Abate by
- May 8, 2007
- Penalty
- Initial $750 · Current $750
1700IV0A01
- Issued
- Apr 25, 2007
- Abate by
- May 8, 2007
- Penalty
- Initial $250 · Current $250
More inspections at FG Auto Corp DBA Autoland
View FG Auto Corp DBA Autoland's full OSHA safety record →
More inspections in this industry (NAICS 441110)
More inspections in PR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308164920.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.