BUCKINGHAM TOWNSHIP, PA —
OSHA Inspection: TRU-LINE CONTRACTORS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRU-LINE CONTRACTORS INC. in GREEN RIDGE ROAD, BUCKINGHAM TOWNSHIP, PA 18925 (NAICS 237110). OSHA activity number 308170752.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRU-LINE CONTRACTORS INC.
- Site address
- GREEN RIDGE ROAD
- City
- BUCKINGHAM TOWNSHIP
- State
- PA
- ZIP
- 18925
- Mailing
- 4388 SKIPPACK PIKE, SCHWENKSVILLE, PA 19473
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- SIC code (legacy)
- 1623
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 27, 2005
- Abate by
- Aug 16, 2005
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees, while engaged in an air test of ductile iron pipe, were exposed to being struck by a ruptured or dislodged pipe plug: a) Wastewater lagoon construction site, Buckingham Township, PA - On or about June 10, 2005 employees engaged in an air test of a 36 inch internal diameter ductile iron pipe were exposed to injury from being struck by a ruptured or dislodged Lansas Domehead pipe plug. Among other methods, one feasible and acceptable abatement method to correct this hazard is to utilize the recommendations of the manufacture contained in the Lansas Products publication entitled Safety Instructions for the Proper Use of Pneumatic Pipe Plugs. These recommendations would include but not be limited to the following: 1. Utilize a properly calibrated gauge for the continuous monitoring of inflation pressures and back test pressures. 2. Use extension hoses and poly lift rope/inflation lines. Be sure you are using a length that allows you to stay clear of the "DANGER ZONE" while pneumatic plugs are in use. 3. Always stay out of the "DANGER ZONE". 4. Blocking or bracing must be used to prevent the movement or complete dislodging of pipe plugs. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.tives