OSHA Inspection: CANTELLO REMODELING SPECIALISTS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CANTELLO REMODELING SPECIALISTS, INC. in 69 BROOKVIEW LANE, POTTSTOWN, PA 19464 (NAICS 238130). OSHA activity number 308172865.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cantello Remodeling Specialists, INC. for free Get an email when a new federal OSHA severe-injury report for Cantello Remodeling Specialists, INC. is published. One employer, no account, unsubscribe in one click.
Site address
69 BROOKVIEW LANE
City
POTTSTOWN
State
PA
ZIP
19464
Mailing
PO BOX 384, PARKER FORD, PA 19457
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Aug 22, 2005
Abate by
Sep 9, 2005
Penalty
Initial $750 · Current $750
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being struck by collapsing truss roof
components due to
inadequate bracing:
a) Worksite - Brookview Lane, Lower Pottsgrove Township, PA 19464 - On or
about
May 22, 2005 a metal plate connected wood truss collapsed during
installation of a
partition wall.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is
to utilize the recommendations of the Truss Plate Institute and Wood Truss
Council of America
publications Building Component Safety Information, Guide to Good Practice
For Handling,
Installing, & Bracing of Metal Plate Connected Wood Trusses BCSI 1-03
These
recommendations would include but not be limited to the following:
1. Provide top cord temporary continuous lateral bracing of appropriate
material a
maximum of 8 feet on center as recommended in the BCSI-B1 publication and
figures
B1-23 & B1-24 contained there in.
2. Provide top cord temporary diagonal bracing for the continuous lateral
bracing method
as recommended in the BCSI-B1 publication and figure B1-24 contained there
in.
3. Provide bottom cord temporary/permanent lateral and diagonal bracing as
recommended in the BCSI-B1 publication and figures B1-25 & B1-26 contained
there in.
4. Provide web member bracing as recommended in the BCSI-B1 publication
and figures
B1-28 contained there in.
Abatement certification required within 10 days after abatement date.  The
certification
shall
include a statement that abatement is complete, date and method of
abatement, and states
employees and their representatives were informed of this abatement.tives

1926.501 B13

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 22, 2005
Abate by
Sep 26, 2005
Penalty
Initial $750 · Current $750

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 308172865.