NIAGARA FALLS, NY —
OSHA Inspection: WENDT'S DAIRY DIVISION NIAGARA MILK COOPERATIVE, I
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of WENDT'S DAIRY DIVISION NIAGARA MILK COOPERATIVE, I in 8450 BUFFALO AVENUE, NIAGARA FALLS, NY 14304 (NAICS 311511). OSHA activity number 308280197.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WENDT'S DAIRY DIVISION NIAGARA MILK COOPERATIVE, I
- Site address
- 8450 BUFFALO AVENUE
- City
- NIAGARA FALLS
- State
- NY
- ZIP
- 14304
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- SIC code (legacy)
- 2026
- Employees
- 98
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 18, 2005
- Abate by
- Apr 22, 2005
- Penalty
- Initial $1,250 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of ammonia inhalation. a) On or about January 19, 2005: Plant Engine Room was not provided with tight-fitting doors. (Reference Source: ANSI/ASHRAE 15-1978, Section 11.13.5a). b) On or about January 19, 2005: Garage Engine Room was not provided with either a continuously operated, independent mechanical ventilation system or electrical equipment which conforms to either the requirements for a Class 1, Division 2 Location as defined in the National Electrical Code (Reference Source: ANSI/ASHRAE 15-1978, Section 7.4.1 et al). Among other methods, feasible and acceptable abatement methods to correct the hazards are to: 1.Repair the existing doors so they are tight fitting for the Plant Engine Room as required by ANSI/ASHRAE 15-1978, Section 11.13.5a. 2.Install a continuously operated, independent mechanical system in the Garage Engine Room as required in Reference Source: ANSI/ASHRAE 15-1978, Section 7.4.1 et al. 3.Install electrical equipment which conforms to either the requirements for a Class 1 Division 2 location as defined in the National Electrical Code as required in Class 1, Division 2 Location as defined in the National Electrical Code ANSI/ASHRAE 15-1978, Section 7.4.1 et al. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $750.00
- — Z (S) $1250.00
1910.22 A01
- Issued
- Feb 18, 2005
- Abate by
- Mar 23, 2005
- Penalty
- Initial $1,000 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1000.00
1910.95 G08 II
- Issued
- Feb 18, 2005
- Abate by
- Mar 8, 2005
- Penalty
- Initial $1,250 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1250.00
1910.95 I02 IIB
- Issued
- Feb 18, 2005
- Abate by
- Mar 8, 2005
- Penalty
- Initial $1,250 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1250.00
1910.133 A01
- Issued
- Feb 18, 2005
- Abate by
- Feb 24, 2005
- Penalty
- Initial $1,250 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1250.00
More inspections at Wendt'S Dairy Division Niagara Milk Cooperative, I
View Wendt'S Dairy Division Niagara Milk Cooperative, I's full OSHA safety record →