HARTFORD, CT —
OSHA Inspection: CLIFFHANGERS JANITORIAL SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLIFFHANGERS JANITORIAL SERVICES, INC. in 100 WELLS STREET, HARTFORD, CT 06103 (NAICS 561720). OSHA activity number 308281609.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLIFFHANGERS JANITORIAL SERVICES, INC.
- Site address
- 100 WELLS STREET
- City
- HARTFORD
- State
- CT
- ZIP
- 06103
- Mailing
- P.O. BOX 124, N. QUINCY, MA 02171
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- SIC code (legacy)
- 7349
- Employees
- 10
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 27, 2006
- Abate by
- Aug 2, 2006
- Penalty
- Initial $625 · Current $313 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to serious fall hazards: Jobsite located at Bushnell on the Park Building, 100 Wells Street, Hartford, CT: Employees of Cliff Hangers Janitorial Services, Inc., performing window washing activities on the exterior of this 10 story building were using rope descent systems consisting of SALA lanyards, Sky Genie boards and descent device racks. Niether the suspension systems nor the lifeline systems were adequately anchored to the building structure. A.Grey Rope System: Both the primary descent rope and the fall arrest rope had been tied back to sheet metal roof vents. The carabiners securing the ropes around the vents had not been closed. B.Orange Rope System: Both the primary descent rope and the fall arrest rope had been tied back to the same anchorage point on a roof mounted chiller unit. Among other methods the following are feasible and acceptable means of abating the hazards: A.Ensure that all tiebacks are attached to certified anchorages that have been identified as capable of sustaining a 5000 pound minimum load in any direction that the load may be applied. B.Ensure that descent ropes and fall arrest rope are secured to independent achorage points.
Recent events (2)
- — I (S) $312.50
- — Z (S) $625.00
More inspections in this industry (NAICS 561720)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308281609.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.