Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GE LIGHTING SYSTEMS, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of GE LIGHTING SYSTEMS, INC. in 3010 SPARTANBURG HWY., EAST FLAT ROCK, NC 28726 (NAICS 335122). OSHA activity number 308286277.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GE Lighting Systems, INC. — free Get an email when a new federal OSHA severe-injury report for GE Lighting Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3010 SPARTANBURG HWY.
City
EAST FLAT ROCK
State
NC
ZIP
28726
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
SIC code (legacy)
3646
Employees
710
Ownership type
A
Industry flags
Manufacturing safety.

52 citations on file for this inspection.

95012901

Other-than-serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish to each of his employees conditions of employment
and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to
employees:
a)annealing area  --  The rated load was not marked on the under the hook
lifting device
which was attached to the the 500 lb. Demag hoist.
Reference:ANSI B30.20-1985, Chapter 20-1, Section 20-1.2 Markings,
Paragraph 20-1.1.2
(a)Rated load marking. The rated load of the lifting device shall be marked
on the structure where it is visible.
(b)Identification.  A nameplate or other permanent marking shall be
affixed displaying the following information:
(1)manufacturer's name
(2)serial number
(3)lifter weight, if over 100 lbs.
(4)rated load
NOTE:   Among other methods, one feasible and acceptable method to correct
this hazard is to
properly mark the rated load on the below the hook lifting device.
Recent events (2)
  • — I (O)
  • — Z (S) $1625.00

95012901

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625 · Current $1,625
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:
The employer did not furnish to each of his employees conditions of
employment and a place of employment
which were free from recognized hazards that were causing or likely to
cause death or serious physical harm to
employees:
a)annealing area  --  Inspections of under the hook lifting devices were
not being conducted at
intervals as required.
Reference:ANSI B30.20-1985, Section 20-1.3 Inspections, Paragraph 20-1.3.1
Inspection
Classification
(a)Prior to initial use, all new, altered, modified, or repaired lifting
devices shall
be inspected by a designated person to ensure compliance with this
standard.
(b)Inspection Intervals.  Inspection procedures for lifters in regular
service
is
divided into two general classifications based upon the intervals at which
inspections are to be performed.
(1)Frequent inspection.
(2)Periodic inspection.
NOTE:   Among other methods, one feasible and acceptable method to correct
this hazard is to conduct
frequent and periodic inspections as required.

95012901

Deleted Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:
The employer did not furnish to each of his employees conditions of
employment and a place of employment
which were free from recognized hazards that were causing or likely to
cause death or serious physical harm to
employees:
a)  annealing area --  The below the hook lifting device, attached to the
500 lb. Demag hoist, had not
not been load tested as required.
Reference:ANSI B30.20-1985, Chapter 20-1, Section 20-1.4 Testing,
Paragraph 20-1.4.1
Operational Tests.  Prior to initial use, all new, altered, modified, or
repaired lifting
deices shall be tested to ensure compliance with this standard, including
the following
functions:
(a)Moving parts.  Lifters with moving parts shall be tested to determine
that a
lifter operates in accordance with the manufacturer's instructions.
(b)Latches.  Lifters with manually operated or automatic latches shall be
tested to
determine that the latch operates in accordance with the manufacturer's
instructions.
NOTE:   Among other methods, one feasible and acceptable method to correct
this hazard is to
properly load test the under the hook lifting device as required.
Recent events (2)
  • — I (S)
  • — Z (S) $1625.00

95012901

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625 · Current $406 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:
The employer did not furnish to each of his employees conditions of
employment and a place of employment
which were free from recognized hazards that were causing or likely to
cause death or serious physical harm to
employees:
a)  die cast maintenance  --  The one-half ton air hoist, manufacturer
unknown, used to lift rolls of
tubing, was not being inspected as required.
Reference:ANSI B30.16-2003, Chapter 16-2, Section 16-2.1 Inspection,
Paragraph 16-2.1.1
Inspection Classification
(a)Prior to initial use, all new, altered, modified hoists shall be
inspected by a
designated person to ensure compliance with this standard.
(b)Inspection Intervals.  Inspection procedures for hoists in regular
service is
divided into two general classifications based upon the intervals at which
inspections should be performed.
(1)Frequent Inspection
(2)Periodic Inspection
NOTE:   Among other methods, one feasible and acceptable method to correct
this hazard is to conduct
hoist inspections as required.ns
Recent events (2)
  • — I (S) $406.25
  • — Z (S) $1625.00

95012901

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625 · Current $406 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:
The employer did not furnish to each of his employees conditions of
employment and a place of employment
which were free from recognized hazards that were causing or likely to
cause death or serious physical harm to
employees:
a)  die cast maintenance area  --  The one-half ton underhung air hoist,
manufacturer unknown, had not
been load tested as required.
b)  ballast cell #5  --  Hoist #C1011, used to lift 55 gallon drums, has
not been load rated.
Reference:ANSI B30.16-2, Section 16-2.2 Testing, Paragraph 16-2.2.2 Load
Tests
(b)Electric Powered or Air Powered Hoists
(1)Complete new hoists shall be dynamically load tested by the
manufacturer as specified in paragraphs 16-2.2.1(b)(1) and (2) with a
load test not less than 125of the rated load, except that if testing
cannot be performed by the manufacturer, the user shall be notified and
the load test shall be accomplished at another location or job site, by or
under the direction of a designated person prior to the hoist being placed
into service.  (The user is testing the complete structure whether or not
the hoist was tested by the manufacturer.)
(c)The person conducting the load test shall prepare a written report of
the load
sustained during the test and the operations performed during the test.
Reports
must be placed on file.
NOTE:  Among other methods, one feasible and acceptable method to correct
this hazard is to load test
the underhung hoists as required and maintain a record of the load test.
Recent events (2)
  • — I (S) $406.25
  • — Z (S) $1625.00

95012901

Other-than-serious 4 instances 10 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625 · Current $1,625
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish to each of his employees conditions of employment
and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to
employees:
a)  coil winding cell #2  --  The safety latch was defective on the Demag
hoist.
b)  alglass department   --  There was no safety latch on the hook on the
two-ton service hoist.
c)  spin lathe department  --  The safety latch was defective on the CM
Loadstar 2-ton hoist.
d)  alzak department  --  The safety latch was defective on the CM
Loadstar 1-ton hoist.
Reference:  ANSI B30.16-2003, Chapter 16-1, Section 16-1.2 Construction,
Paragraph 16-1.2.9 Hooks
(a)     If hooks are of the swiveling type, they should rotate freely.
Hooks shall be
equipped with latches unless use of the latch creates a hazardous
condition.
NOTE:  Among other methods, one feasible and acceptable method to correct
this hazard is to
inspect the hooks and ensure that the hooks have safety latches in good
condition.
Recent events (2)
  • — I (O) $1625.00
  • — Z (S) $1625.00

95012901

Serious 2 instances 10 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625 · Current $406 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:
The employer did not furnish to each of his employees conditions of
employment and a place of employment
which were free from recognized hazards that were causing or likely to
cause death or serious physical harm to
employees:
a)  powder paint department  --  The upper rail had capacity marked at 500
lbs., the rail just below, and
attached to the upper rail,  had  capacity marked at 100 lbs., and the CM
hoist on this system had
capacity marked at 300 lbs.
Reference:  ANSI B30.11-1998, Chapter 11-1, Section 11-1.1 Markings,
Paragraph 11-1.1.1 Rated Load
Markings-Crane.  The rated load of the crane shall be marked on the crane
and if the crane
has more than one hoisting unit, each hoist shall have its rated load
marked on the hoist or
its load block so that the rated load marking shall be legible from the
ground or floor.  The
combined load on all hoists on the crane shall not exceed the rated load
of the crane.
NOTE:  Among other methods, one feasible and acceptable method to correct
this hazard is to
properly mark the rated load on the components of the system and train
employees
never to
attempt to lift more than the lowest rated load in the system.
Recent events (2)
  • — I (S) $406.25
  • — Z (S) $1625.00

1910.23 C01

Serious 2 instances 2 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005
Penalty
Initial $813 · Current $813

1910.106 G03 III

Other-than-serious 1 instance 6 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625
Recent events (2)
  • — I (O)
  • — Z (S) $1625.00

1910.106 E06 II

Deleted Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005
Recent events (2)
  • — I (S)
  • — Z (S)

1910.106 E09 III

Other-than-serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005
Recent events (2)
  • — I (O)
  • — Z (S)

1910.179 N03 IV

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 30, 2005
Penalty
Initial $1,625 · Current $1,625
Recent events (2)
  • — P (S) $1625.00
  • — Z (S) $1625.00

1910.179 B04

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 B05

Serious 2 instances 6 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 E02 I

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 30, 2005
Recent events (2)
  • — P (S)
  • — Z (S)

1910.179 G01 V

Serious 6 instances 6 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 H01 II

Serious 2 instances 6 exposed
Issued
Apr 28, 2005
Abate by
May 17, 2005

1910.179 J02

Serious 40 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 J03

Serious 40 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 J02 III

Serious 125 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 J02 IV

Serious 40 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 K02

Serious 10 instances 40 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 L01

Serious 40 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 M01

Serious 40 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 N04 I

Serious 125 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.179 D05 III

Serious 2 instances 8 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.180 D06

Serious 2 instances 6 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,625 · Current $1,625

1910.180 E02 I

Serious 2 instances 6 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.180 G01

Serious 2 instances 6 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.184 F05 III

Serious 1 instance 6 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005
Penalty
Initial $1,625 · Current $1,625

1910.184 E01

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005

1910.184 E04

Serious 1 instance 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.212 A03 II

Serious 2 instances 12 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005
Penalty
Initial $813 · Current $813

1910.217 E01 II

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005
Penalty
Initial $6,300 · Current $6,300

1910.217 E01 I

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005

1910.217 E03

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005

1910.217 B07 VA

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005

1910.217 D06 I

Serious 40 instances 20 exposed
Issued
Apr 28, 2005
Abate by
Jun 30, 2005
Recent events (2)
  • — P (S)
  • — Z (S)

1910.219 D01

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005
Penalty
Initial $488 · Current $488

1910.219 E01 I

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.303 B02

Serious 1 instance 6 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005
Penalty
Initial $813 · Current $813

1910.304 F04

Serious 10 instances 40 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.305 B01

Serious 3 instances 4 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005

1910.305 D

Serious 1 instance 2 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005

1910.22 A02

Other-than-serious 2 instances 10 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.151 C

Deleted Other-than-serious 1 instance 1 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005
Recent events (2)
  • — I (O)
  • — Z (O)

1910.157 C01

Other-than-serious 1 instance 6 exposed
Issued
Apr 28, 2005
Abate by
May 10, 2005

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005

1910.157 F02

Other-than-serious 1 instance 3 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005

1910.303 G01 II

Other-than-serious 4 instances 3 exposed
Issued
Apr 28, 2005
Abate by
May 3, 2005

1910.305 G01 IIIA

Other-than-serious 12 instances 50 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005

1910.305 G02 III

Other-than-serious 2 instances 4 exposed
Issued
Apr 28, 2005
Abate by
Jun 15, 2005