EAST FLAT ROCK, NC —
OSHA Inspection: GE LIGHTING SYSTEMS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of GE LIGHTING SYSTEMS, INC. in 3010 SPARTANBURG HWY., EAST FLAT ROCK, NC 28726 (NAICS 335122). OSHA activity number 308286277.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GE LIGHTING SYSTEMS, INC.
- Site address
- 3010 SPARTANBURG HWY.
- City
- EAST FLAT ROCK
- State
- NC
- ZIP
- 28726
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335122
- SIC code (legacy)
- 3646
- Employees
- 710
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
52 citations on file for this inspection.
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)annealing area -- The rated load was not marked on the under the hook lifting device which was attached to the the 500 lb. Demag hoist. Reference:ANSI B30.20-1985, Chapter 20-1, Section 20-1.2 Markings, Paragraph 20-1.1.2 (a)Rated load marking. The rated load of the lifting device shall be marked on the structure where it is visible. (b)Identification. A nameplate or other permanent marking shall be affixed displaying the following information: (1)manufacturer's name (2)serial number (3)lifter weight, if over 100 lbs. (4)rated load NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to properly mark the rated load on the below the hook lifting device.
Recent events (2)
- — I (O)
- — Z (S) $1625.00
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625 · Current $1,625
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)annealing area -- Inspections of under the hook lifting devices were not being conducted at intervals as required. Reference:ANSI B30.20-1985, Section 20-1.3 Inspections, Paragraph 20-1.3.1 Inspection Classification (a)Prior to initial use, all new, altered, modified, or repaired lifting devices shall be inspected by a designated person to ensure compliance with this standard. (b)Inspection Intervals. Inspection procedures for lifters in regular service is divided into two general classifications based upon the intervals at which inspections are to be performed. (1)Frequent inspection. (2)Periodic inspection. NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to conduct frequent and periodic inspections as required.
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) annealing area -- The below the hook lifting device, attached to the 500 lb. Demag hoist, had not not been load tested as required. Reference:ANSI B30.20-1985, Chapter 20-1, Section 20-1.4 Testing, Paragraph 20-1.4.1 Operational Tests. Prior to initial use, all new, altered, modified, or repaired lifting deices shall be tested to ensure compliance with this standard, including the following functions: (a)Moving parts. Lifters with moving parts shall be tested to determine that a lifter operates in accordance with the manufacturer's instructions. (b)Latches. Lifters with manually operated or automatic latches shall be tested to determine that the latch operates in accordance with the manufacturer's instructions. NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to properly load test the under the hook lifting device as required.
Recent events (2)
- — I (S)
- — Z (S) $1625.00
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625 · Current $406 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) die cast maintenance -- The one-half ton air hoist, manufacturer unknown, used to lift rolls of tubing, was not being inspected as required. Reference:ANSI B30.16-2003, Chapter 16-2, Section 16-2.1 Inspection, Paragraph 16-2.1.1 Inspection Classification (a)Prior to initial use, all new, altered, modified hoists shall be inspected by a designated person to ensure compliance with this standard. (b)Inspection Intervals. Inspection procedures for hoists in regular service is divided into two general classifications based upon the intervals at which inspections should be performed. (1)Frequent Inspection (2)Periodic Inspection NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to conduct hoist inspections as required.ns
Recent events (2)
- — I (S) $406.25
- — Z (S) $1625.00
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625 · Current $406 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) die cast maintenance area -- The one-half ton underhung air hoist, manufacturer unknown, had not been load tested as required. b) ballast cell #5 -- Hoist #C1011, used to lift 55 gallon drums, has not been load rated. Reference:ANSI B30.16-2, Section 16-2.2 Testing, Paragraph 16-2.2.2 Load Tests (b)Electric Powered or Air Powered Hoists (1)Complete new hoists shall be dynamically load tested by the manufacturer as specified in paragraphs 16-2.2.1(b)(1) and (2) with a load test not less than 125of the rated load, except that if testing cannot be performed by the manufacturer, the user shall be notified and the load test shall be accomplished at another location or job site, by or under the direction of a designated person prior to the hoist being placed into service. (The user is testing the complete structure whether or not the hoist was tested by the manufacturer.) (c)The person conducting the load test shall prepare a written report of the load sustained during the test and the operations performed during the test. Reports must be placed on file. NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to load test the underhung hoists as required and maintain a record of the load test.
Recent events (2)
- — I (S) $406.25
- — Z (S) $1625.00
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625 · Current $1,625
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) coil winding cell #2 -- The safety latch was defective on the Demag hoist. b) alglass department -- There was no safety latch on the hook on the two-ton service hoist. c) spin lathe department -- The safety latch was defective on the CM Loadstar 2-ton hoist. d) alzak department -- The safety latch was defective on the CM Loadstar 1-ton hoist. Reference: ANSI B30.16-2003, Chapter 16-1, Section 16-1.2 Construction, Paragraph 16-1.2.9 Hooks (a) If hooks are of the swiveling type, they should rotate freely. Hooks shall be equipped with latches unless use of the latch creates a hazardous condition. NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to inspect the hooks and ensure that the hooks have safety latches in good condition.
Recent events (2)
- — I (O) $1625.00
- — Z (S) $1625.00
95012901
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625 · Current $406 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) powder paint department -- The upper rail had capacity marked at 500 lbs., the rail just below, and attached to the upper rail, had capacity marked at 100 lbs., and the CM hoist on this system had capacity marked at 300 lbs. Reference: ANSI B30.11-1998, Chapter 11-1, Section 11-1.1 Markings, Paragraph 11-1.1.1 Rated Load Markings-Crane. The rated load of the crane shall be marked on the crane and if the crane has more than one hoisting unit, each hoist shall have its rated load marked on the hoist or its load block so that the rated load marking shall be legible from the ground or floor. The combined load on all hoists on the crane shall not exceed the rated load of the crane. NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to properly mark the rated load on the components of the system and train employees never to attempt to lift more than the lowest rated load in the system.
Recent events (2)
- — I (S) $406.25
- — Z (S) $1625.00
1910.23 C01
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
- Penalty
- Initial $813 · Current $813
1910.106 G03 III
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625
Recent events (2)
- — I (O)
- — Z (S) $1625.00
1910.106 E06 II
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
Recent events (2)
- — I (S)
- — Z (S)
1910.106 E09 III
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
Recent events (2)
- — I (O)
- — Z (S)
1910.179 N03 IV
- Issued
- Apr 28, 2005
- Abate by
- Jun 30, 2005
- Penalty
- Initial $1,625 · Current $1,625
Recent events (2)
- — P (S) $1625.00
- — Z (S) $1625.00
1910.179 B04
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 B05
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 E02 I
- Issued
- Apr 28, 2005
- Abate by
- Jun 30, 2005
Recent events (2)
- — P (S)
- — Z (S)
1910.179 G01 V
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 H01 II
- Issued
- Apr 28, 2005
- Abate by
- May 17, 2005
1910.179 J02
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 J03
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 J02 III
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 J02 IV
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 K02
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 L01
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 M01
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 N04 I
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.179 D05 III
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.180 D06
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $1,625 · Current $1,625
1910.180 E02 I
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.180 G01
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.184 F05 III
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
- Penalty
- Initial $1,625 · Current $1,625
1910.184 E01
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
1910.184 E04
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.212 A03 II
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
- Penalty
- Initial $813 · Current $813
1910.217 E01 II
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
- Penalty
- Initial $6,300 · Current $6,300
1910.217 E01 I
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
1910.217 E03
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
1910.217 B07 VA
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
1910.217 D06 I
- Issued
- Apr 28, 2005
- Abate by
- Jun 30, 2005
Recent events (2)
- — P (S)
- — Z (S)
1910.219 D01
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
- Penalty
- Initial $488 · Current $488
1910.219 E01 I
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.303 B02
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
- Penalty
- Initial $813 · Current $813
1910.304 F04
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.305 B01
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
1910.305 D
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
1910.22 A02
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.151 C
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
Recent events (2)
- — I (O)
- — Z (O)
1910.157 C01
- Issued
- Apr 28, 2005
- Abate by
- May 10, 2005
1910.157 E03
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
1910.157 F02
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
1910.303 G01 II
- Issued
- Apr 28, 2005
- Abate by
- May 3, 2005
1910.305 G01 IIIA
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
1910.305 G02 III
- Issued
- Apr 28, 2005
- Abate by
- Jun 15, 2005
More inspections at GE Lighting Systems, INC.
View GE Lighting Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335122)
More inspections in NC
Source