PAWNEE, TX ·
OSHA Inspection: TONG SPECIALTY, LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of TONG SPECIALTY, LLC in FM 72 NEAR PAWNEE,KUENSTER #1, PAWNEE, TX 78145 (NAICS 213112). OSHA activity number 308310770.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TONG SPECIALTY, LLC
- Site address
- FM 72 NEAR PAWNEE,KUENSTER #1
- City
- PAWNEE
- State
- TX
- ZIP
- 78145
- Mailing
- 2500 BUSINESS 281 NORTH, ALICE, TX 78332
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 7
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 18, 2005
- Abate by
- Jun 14, 2005
- Penalty
- Initial $56,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck by hazard: On or about December 27, 2004, worn parts and/or parts substituted for manufacturer approved replacement parts were used on BJ slip-type elevator spider assembly in use on Rig Number 183. Among methods of corrections, feasible and acceptable abatement methods to correct this hazard includes complying with manufacturer's requirement in the BJ Hughes Operating Service and Parts Manual and the International Association of Drilling Contractors' Drilling Manual, 1992 edition, in the design and implementation of a comprehensive inspection program for all hoisting tools, including elevator and slip assemblies. This program would include, but not be limited to: a.A combination of field daily inspections, monthly inspections, quarterly inspections and disassembly inspections. b.Inspections and maintenance repairs would be made only by technically competent personnel. c.Written records of all inspection and maintenance procedures would be maintained. d.Only approved replacement parts would be used to make repairs.ent
Recent events (2)
- · F (W)
- · Z (W) $56000.00
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308310770.