OSHA Inspection: TONG SPECIALTY, LLC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of TONG SPECIALTY, LLC in FM 72 NEAR PAWNEE,KUENSTER #1, PAWNEE, TX 78145 (NAICS 213112). OSHA activity number 308310770.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tong Specialty, LLC for free Get an email when a new federal OSHA severe-injury report for Tong Specialty, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TONG SPECIALTY, LLC
Site address
FM 72 NEAR PAWNEE,KUENSTER #1
City
PAWNEE
State
TX
ZIP
78145
Mailing
2500 BUSINESS 281 NORTH, ALICE, TX 78332
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
7
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Willful Gravity 10 1 instance 3 exposed
Issued
May 18, 2005
Abate by
Jun 14, 2005
Penalty
Initial $56,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a struck by hazard:
On or about December 27, 2004, worn parts and/or parts substituted for
manufacturer approved replacement parts were used on BJ slip-type elevator
spider assembly in use on Rig Number 183.
Among methods of corrections, feasible and acceptable abatement methods to
correct this hazard includes complying with manufacturer's requirement in
the BJ
Hughes Operating Service and Parts Manual and the International
Association of
Drilling Contractors' Drilling Manual, 1992 edition, in the design and
implementation of a comprehensive inspection  program for all hoisting
tools,
including elevator and slip assemblies.  This program would include, but
not be
limited to:
a.A combination of field daily inspections, monthly  inspections,
quarterly
inspections and disassembly inspections.
b.Inspections and maintenance repairs would be made only by technically
competent personnel.
c.Written records of all inspection and maintenance procedures would be
maintained.
d.Only approved replacement parts would be used to make repairs.ent
Recent events (2)
  • · F (W)
  • · Z (W) $56000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308310770.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.