On , OSHA opened a referral safety inspection of DATUM CONSTRUCTION MANAGEMENT, INC. in 109 WEST PINE, CASCADE, ID 83611 (NAICS 236220). OSHA activity number 308341981.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Datum Construction Management, INC. — free Get an email when a new federal OSHA severe-injury report for Datum Construction Management, INC. is published. One employer, no account, unsubscribe in one click.
Site address
109 WEST PINE
City
CASCADE
State
ID
ZIP
83611
Mailing
12554 W. BRIDGER STREET, BOISE, ID 83713
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
SIC code (legacy)
1542
Employees
2
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 8 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Penalty
Initial $1,500 · Current $900 Reduced
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:The
employer did not furnish employment and
a place of employment which were free from recognized hazards that were
causing or likely to cause death or
serious physical harm to employees in that employees were exposed to
structural collapse:
a)South exterior wall of the Sanctuary - Cascade Community Church - 109
West Pine, Cascade, ID; On
or about 10/26/05 and at times prior thereto, as the controlling employer,
it was not determined/ensured
that a load-bearing exterior wall was adequately constructed and laterally
supported prior to placing
roof trusses onto the wall, thereby exposing employees working
on/around/under the wall and/or
trusses to the hazard of being struck by the collapsing structure.
Note: Among other methods, one feasible and acceptable abatement method
to correct this hazard would be
following the temporary bracing requirements for roof truss installation
per the Truss Manufacturer and/or
Wood Truss Council of America's "Building Component Safety Information"
Bulletin BCSI 1-03.
b)Sanctuary area - Cascade Community Church - 109 West Pine, Cascade, ID;
On or about 10/26/05 and
at times prior thereto, as the controlling employer, it was not
determined/ensured that roof trusses
were laterally supported with diagonal bracing as they were installed,
thereby exposing employees
working on/around/under the wall and/or trusses to the hazard of being
struck by the collapsing
structure.
Note:  Among other methods, one feasible and acceptable abatement method
to correct this hazard would be
following the temporary bracing requirements for roof truss installation
per the Truss Manufacturer and/or
Wood Truss Council of America's "Building Component Safety Information"
Bulletin BCSI 1-03.
Recent events (2)
  • — I (S) $900.00
  • — Z (S) $1500.00

5(a)(1)

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:The
employer did not furnish employment and
a place of employment which were free from recognized hazards that were
causing or likely to cause death or
serious physical harm to employees in that employees were exposed to
structural collapse:
a)South side staging area and Sanctuary area - Cascade Community Church -
109 West Pine, Cascade,
ID; On or about 10/26/05 and at times prior thereto, as the controlling
employer, it was not ensured that
a spreader bar or "stiffback" was utilized for hoisting/placing roof
trusses with a span greater than 30
feet, thereby exposing employees working on/around/under the trusses
and/or parts of the structure to
the hazard of being struck by the collapsing truss or structural collapse.
Note: Among other methods, one feasible and acceptable abatement method
to correct this hazard would be
following the hoisting requirements for roof trusses with a span greater
than 30 feet per the Truss
Manufacturer and/or Wood Truss Council of America's "Building Component
Safety Information" Bulletin
BCSI 1-03.
Recent events (2)
  • — I (S)
  • — Z (S)

1926.501 B01

Serious Gravity 10 2 instances 3 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Penalty
Initial $1,500 · Current $900 Reduced
Recent events (2)
  • — I (S) $900.00
  • — Z (S) $1500.00

1926.550 A09

Other-than-serious Gravity 01 1 instance 9 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Recent events (2)
  • — I (O)
  • — Z (O)

View Datum Construction Management, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308341981.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.