DARIEN, WI —
OSHA Inspection: PROFESSIONAL POWER PRODUCTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PROFESSIONAL POWER PRODUCTS, INC. in 448 W. MADISON STREET, DARIEN, WI 53114 (NAICS 335313). OSHA activity number 308383991.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROFESSIONAL POWER PRODUCTS, INC.
- Site address
- 448 W. MADISON STREET
- City
- DARIEN
- State
- WI
- ZIP
- 53114
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335313
- SIC code (legacy)
- 3613
- Employees
- 80
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- May 26, 2006
- Abate by
- Jul 31, 2006
- Penalty
- Initial $4,200 · Current $1,680 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Employees operating the Accurpress hydraulic press brake were exposed to crushing and/or amputation hazards due to the lack of point-of-operations guards or safety devices. Among other methods, feasible and acceptable abatement methods to correct this hazard would be to: Comply with the American National Standard Institute (ANSI) B11.3-1982, section 6.1.4(1), Safety Requirements for Power Press Brakes. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that the abatement is complete must be included with your certification. This documentation may include, but is not to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1680.00
- — Z (S) $4200.00
1910.23 C01
- Issued
- May 26, 2006
- Abate by
- Sep 30, 2006
- Penalty
- Initial $2,100 · Current $840 Reduced
Recent events (2)
- — I (S) $840.00
- — Z (S) $2100.00
1910.212 A03 II
- Issued
- May 26, 2006
- Abate by
- Jun 13, 2006
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.178 Q07
- Issued
- May 26, 2006
- Abate by
- Jun 13, 2006
Recent events (2)
- — I (O)
- — Z (O)
1910.179 J02 I
- Issued
- May 26, 2006
- Abate by
- Jun 1, 2006
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Professional Power Products, INC.
View Professional Power Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335313)