Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: M.T. KELLEY ELECTRICAL SERVICE

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of M.T. KELLEY ELECTRICAL SERVICE in MARINER'S WALK CONDO, FERNANDINA BEACH, FL 32034 (NAICS 238210). OSHA activity number 308431667.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M.T. Kelley Electrical Service for free Get an email when a new federal OSHA severe-injury report for M.T. Kelley Electrical Service is published. One employer, no account, unsubscribe in one click.
Site address
MARINER'S WALK CONDO
City
FERNANDINA BEACH
State
FL
ZIP
32034
Mailing
P.O. BOX 521, FERNANDINA BEACH, FL 32035
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
Yes
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
4
Ownership type
Private (A)

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 2 exposed
Issued
Aug 31, 2005
Abate by
Sep 6, 2005
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to falling:
a.On or about June 9, 2005, at the Mariner's Walk job site, the employer
used the
Asplundh Model L45 aerial lift in a manner for which it was not intended;
that
is, as a crane to pull on and lift power poles while an employee was
elevated in
the bucket.
Among other methods, feasible and acceptable abatement methods to correct
the hazard
is to ensure that the aerial lift is only used for the intended purpose
and not as a crane,
do not allow employees to be elevated in the aerial lift if there is any
additional load on
the boom, and provide a crane to assist in the removing and movement of
large objects
such as poles. (Reference ANSI/SIA A92.2 - 1990, Vehicle-Mounted Elevating
and
Rotating Aerial Devices, Section 8.13.2.)
ABATEMENT CERTIFICATION IS NOT REQUIRED.TION

1926.453 B02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 31, 2005
Abate by
Sep 6, 2005

1926.453 B02 VI

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 31, 2005
Abate by
Sep 6, 2005

1926.453 B02 IX

Serious Gravity 03 1 instance 4 exposed
Issued
Aug 31, 2005
Abate by
Sep 27, 2005

1926.454 A

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 31, 2005
Abate by
Sep 13, 2005

1926.20 B01

Other-than-serious Gravity 01 1 instance 5 exposed
Issued
Aug 31, 2005
Abate by
Sep 27, 2005

View M.T. Kelley Electrical Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 308431667.