APOPKA, FL ·
OSHA Inspection: FLORIDA BUILDING MATERIALS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLORIDA BUILDING MATERIALS, INC. in 2983 WEST ORANGE AVE, APOPKA, FL 32776 (NAICS 327331). OSHA activity number 308465319.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLORIDA BUILDING MATERIALS, INC.
- Site address
- 2983 WEST ORANGE AVE
- City
- APOPKA
- State
- FL
- ZIP
- 32776
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327331
- SIC code (legacy)
- 3271
- Employees
- 19
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 25, 2005
- Abate by
- May 12, 2005
- Penalty
- Initial $1,000 · Current $500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by fragments of plastic pipe used to transport compressed air for the operation of air operated tools and air used for cleaning, in the event the piping ruptures: a. Throughout the cement block manufacturing area, polyvinyl chloride ( PVC ) plastic pipe was used to transport compressed air in exposed above ground locations, for the operation of air operated equipment, tools, machines and air used for cleaning, a practice not recommended by the Plastics Pipe Institute and prohibited by ANSI/ASME B31.8-1986, Gas Transmission and Distribution Piping Systems standard, on or about 9/1/94. Among other methods one feasible and acceptable method to correct this hazard is to replace the PVC piping with a type that is approved for transporting compressed gases in exposed above ground locations, such as iron, steel piping, or plastic piping designed for compressed air applications.
Recent events (2)
- · I (S) $500.00
- · Z (S) $1000.00
1910.23 C01
- Issued
- Apr 25, 2005
- Abate by
- May 12, 2005
- Penalty
- Initial $750 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $750.00
1910.27 C04
- Issued
- Apr 25, 2005
- Abate by
- May 12, 2005
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $1250.00
1910.27 D02
- Issued
- Apr 25, 2005
- Abate by
- May 12, 2005
1910.132 D01
- Issued
- Apr 25, 2005
- Abate by
- May 5, 2005
- Penalty
- Initial $750 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $750.00
1910.136 A
- Issued
- Apr 25, 2005
- Abate by
- May 5, 2005
1910.147 C04 I
- Issued
- Apr 25, 2005
- Abate by
- May 28, 2005
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- · I (S) $1250.00
- · Z (S) $2500.00
1910.242 B
- Issued
- Apr 25, 2005
- Abate by
- Apr 29, 2005
- Penalty
- Initial $750 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $750.00
1910.169 B03 IV
- Issued
- Apr 25, 2005
- Abate by
- Apr 29, 2005
Recent events (2)
- · I (S)
- · Z (S)
1910.178 L01 I
- Issued
- Apr 25, 2005
- Abate by
- May 28, 2005
- Penalty
- Initial $1,000 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $1000.00
1910.212 A01
- Issued
- Apr 25, 2005
- Abate by
- May 5, 2005
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- · I (S) $1250.00
- · Z (S) $2500.00
1910.219 F03
- Issued
- Apr 25, 2005
- Abate by
- May 12, 2005
- Penalty
- Initial $1,250
Recent events (2)
- · I (S)
- · Z (S) $1250.00
1910.305 G01 IIIA
- Issued
- Apr 25, 2005
- Abate by
- Apr 29, 2005
- Penalty
- Initial $750 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $750.00
1910.305 G01 IIID
- Issued
- Apr 25, 2005
- Abate by
- May 13, 2005
Recent events (2)
- · I (S)
- · Z (S)
1910.305 G02 II
- Issued
- Apr 25, 2005
- Abate by
- Apr 29, 2005
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 H
- Issued
- Apr 25, 2005
- Abate by
- May 12, 2005
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Florida Building Materials, INC.
View Florida Building Materials, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327331)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308465319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.