CORPUS CHRISTI, TX ·
OSHA Inspection: JALCO, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JALCO, INC in POWER/BROADWAY, CORPUS CHRISTI, TX 78401 (NAICS 237110). OSHA activity number 308469253.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JALCO, INC
- Site address
- POWER/BROADWAY
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78401
- Mailing
- P.O. BOX 27368, HOUSTON, TX 77227
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- SIC code (legacy)
- 1623
- Employees
- 50
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 17, 2005
- Abate by
- Jun 23, 2005
- Penalty
- Initial $4,000 · Current $5,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to atmospheric hazards: a.On February 15, 2005 an employee removing a sewer plug in a manhole approximately 15 ft deep was overcome by a hazardous gas and was rendered unconscious and hospitalized. No air monitoring for hazardous atmospheres or oxygen was conducted prior to employee entry. b.On February 15, 2005 and times prior thereto, employees installing and removing sewer plugs in manholes approximately 15 ft deep were not provided mechanical ventilation. Ventilation fan was removed prior to employee's entry. No mechanical ventilation was provided during entry. c.On February 15, 2005 an employee removing a sewer plug from a 15 ft deep manhole was not provided rescue equipment by the employer in case of an emergency. A feasible means of abatement would be to provide atmospheric testing of confined spaces prior to each employee entry, to ventilate the confined space before and throughout entry procedures by use of blowers and associated ductwork and to provide a tripod, lifeline and body harness to all confined space entrants.
Recent events (2)
- · J (S) $5000.00
- · Z (S) $4000.00
1910.134 A02
- Issued
- Jun 17, 2005
- Abate by
- Jun 23, 2005
- Penalty
- Initial $1,500 · Current $5,000
Recent events (2)
- · J (S) $5000.00
- · Z (S) $1500.00
1926.21 B06 I
- Issued
- Jun 17, 2005
- Abate by
- Jun 29, 2005
- Penalty
- Initial $900 · Current $1,800
Recent events (2)
- · J (S) $1800.00
- · Z (S) $900.00
1926.1051 A
- Issued
- Jun 17, 2005
- Abate by
- Jun 23, 2005
- Penalty
- Initial $1,500
Recent events (2)
- · J (S)
- · Z (S) $1500.00
More inspections at Jalco, INC
View Jalco, INC's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 308469253.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.