OSHA Inspection: BERGMAN FARM SUPPLY, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of BERGMAN FARM SUPPLY, INC. in 1304 BUCHANAN, CARTHAGE, IL 62321 (NAICS 453998). OSHA activity number 308571991.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bergman Farm Supply, INC. — free Get an email when a new federal OSHA severe-injury report for Bergman Farm Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1304 BUCHANAN
City
CARTHAGE
State
IL
ZIP
62321
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
SIC code (legacy)
5999
Employees
5
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 24, 2006
Abate by
Sep 8, 2006
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees, including:
An employee installing two Aaladin hot water pressure cleaners at Eagle
Point Farms was
exposed to burns from fire and explosion hazards and did not did not
ensure the gas pressure
leading to the units measured 11 inches (6.36 Oz.) of water column
pressure prior to
installing the units and attempting to light the pilot light for the units
with a lighter.  The
employer had not developed clear procedures to ensure the employees
verified the maximum
inlet gas pressure prior to installing and lighting the units.
Among other methods, one feasible and acceptable abatement methods to
correct this hazard
is:
1.Ensure that propane gas fired machines operate on 11 inches (6.36 oz)
water column
pressure and that a gas regulator of sufficient size to allow for pressure
drop from the tank to
the machine is installed on the LP tank.  Check the 11 inch water column
at the valve.
Ensure the maximum inlet gas pressure is = PSI (14 inches water column or
8.09 oz per
square inch) for LP gas machines.
2.Develop a clear procedure that requires employees installing units to
use a calibrated
measuring device to verify the gas pressure entering the hot water
pressure cleaners is
appropriate for the unit prior to installation and lighting.
3.Require by contract the host facility to install systems meeting the
specifications of
the hot water pressure cleaners being installed and provide evidence that
the systems meet the
specifications for the unit prior to installation and lighting.
4.Hire a professional contractor to verify the systems that will be used
to provide
Butane or Propane to the hot water pressure cleaners meet the system
specifications for the
particular unit prior to installation and lighting.
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1904.39 A

Other-than-serious Gravity 00 1 instance 3 exposed
Issued
Jul 24, 2006
Abate by
Jul 27, 2006
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — I (O) $750.00
  • — Z (O) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308571991.