LUKE AFB, AZ ·
OSHA Inspection: U.S.AIR FORCE 56TH LOGISTICS READINESS SQUADRON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S.AIR FORCE 56TH LOGISTICS READINESS SQUADRON in BLDG. 945 LUKE AFB, LUKE AFB, AZ 85309 (NAICS 493110). OSHA activity number 308578707.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S.AIR FORCE 56TH LOGISTICS READINESS SQUADRON
- Site address
- BLDG. 945 LUKE AFB
- City
- LUKE AFB
- State
- AZ
- ZIP
- 85309
- Mailing
- 7046 FIGHTER COUNTRY AVE., LUKE AFB, AZ 85309
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- SIC code (legacy)
- 4225
- Employees
- 890
- Ownership type
- Federal government (D)
Citations
3 citations on file for this inspection.
1960.8 A
- Issued
- Apr 11, 2005
- Abate by
- May 4, 2005
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an injury from a vertical lift door which did not provide the door or door operator with a means for connection of a reversing edge switch or equivalent that will reverse the direction of the door upon striking an object during the closing cycle. a).Motor Pool, East side garage door: The vertical lift door did not have an operational reversing edge switch which upon striking an object during the closing cycle would reverse the direction of door. b)Motor Pool, West side garage door: The vertical lift door did not have an operational reversing edge switch which upon striking an object would reverse the direction of the door. Among other methods, one feasible and acceptable abatement method to correct this hazard is to repair the reversing switch mechanism; or to place warning placards at the door controls instructing the door operator to ensure the doorway is cleared and to stand by the controls until the door completes the closing cycle.
1910.147 C02 II
- Issued
- Apr 11, 2005
- Abate by
- Apr 25, 2005
1910.178 Q01
- Issued
- Apr 11, 2005
- Abate by
- Apr 25, 2005
More inspections in this industry (NAICS 493110)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 308578707.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.