NEW YORK, NY —
OSHA Inspection: NEW YORK ELEVATOR INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NEW YORK ELEVATOR INC. in 14 EAST 60TH STREET, NEW YORK, NY 10022 (NAICS 238290). OSHA activity number 308661693.
Where did this inspection happen?
- Establishment
- NEW YORK ELEVATOR INC.
- Site address
- 14 EAST 60TH STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10022
- Mailing
- 519 8TH AVE. (12TH FLOOR), NEW YORK, NY 10018
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- SIC code (legacy)
- 1796
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employees were exposed to being crushed by moving elevator counterweight. a)Elevator machine room at 14 East 60th Street. Employee placed a part of his body in the runway of an adjacent operational counterweight while snaking wires for another elevator, on or about 5/24/05. ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD, AMONG OTHERS, TO CORRECT THIS HAZARD IS: to follow the employers energy control program in the employer`s Safety and Accident Prevention Program, Section 14, Page 1, where it states that "Employees will not perform any work on equipment where there is a potential to come in contact with energized mechanical or electrical hazards until all sources of energy have been de- energized, grounded, or guarded to protect the employees". and/or American National Standards Institute (ANSI) Z244.1-93, for personnel protection, lockout/tagout of energy sources, minimum safety requirements. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION AND DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19NCE
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $4500.00
Recent events (2)
- — F (S) $4500.00
- — Z (S) $4500.00
More inspections in this industry (NAICS 238290)
PRESTONSBURG, KY—2026-06-23
69242 - R - H CONTRACTING LLC
FONTANA, CA—2026-06-18
MOBILE MEDICAL TECHNOLOGIES
LE ROY, NY—2026-06-17
CHUCK MCLAUGHLIN LLC
AURORA, IL—2026-06-10
PEPPER CONSTRUCTION
SALT LAKE CITY, UT—2026-06-04
SOLID CONSTRUCTION GROUP LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308661693.