LAS VEGAS, NV —
OSHA Inspection: EXECUTIVE WINDOW CLEANING & HIGH REACH SPECIALIST
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EXECUTIVE WINDOW CLEANING & HIGH REACH SPECIALIST in 4000 WEST FLAMINGO ROAD, LAS VEGAS, NV 89103 (NAICS 561790). OSHA activity number 308701143.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EXECUTIVE WINDOW CLEANING & HIGH REACH SPECIALIST
- Site address
- 4000 WEST FLAMINGO ROAD
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89103
- Mailing
- 6269 INDUSTRIAL ROAD, BUILDING D, LAS VEGAS, NV 89118
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 2
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
618037501
- Issued
- Aug 31, 2005
- Abate by
- Oct 3, 2005
- Penalty
- Initial $375 · Current $375
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to ensure that place of employment was free from recognized hazards, as follows: a.Gold Coast Hotel and Casino, window cleaning operation, two employees were using anchor points not approved and designed for a minimum 5000 pounds or 4-to-1 safety factor. Metal pipes, 3" in diameter, 7 feet long, Schedule 40, were used by employees to tie off the boatswain's chair work line and the personal safety lifeline. Reference: ANSI/IWCA I-14.1 - 2001, "Window Cleaning Safety", Section 3.9 and Section 9.1.1 (*): Building owners and window cleaning contractors shall not allow suspended work to be performed unless it has been determined that the building has provided, identified and certified anchorages complying with Section 9 or 10 for: independent safety lines; tie-backs; parapet clamps and cornice hooks; primary support anchorages for powered and manual boatswain's chairs; primary support anchorages for rope descent systems or lifelines. (*) Anchorages shall be capable of sustaining a 5000 pounds minimum load or 4-to-1 safety factor, whichever is greater, in any direction that a load may be applied. b.Gold Coast Hotel and Casino, window cleaning operations, employees were allowed to use a manual boatswain's chair where the height of suspension exceeded 75 feet above grade. The Gold Coast tower was approximately 105 feet in height. Reference: ANSI/IWCA I-14.1 - 2001, "Window Cleaning Safety", Section 5.6.5: Manual swinging scaffold and boatswain's chairs may be used for window cleaning operations only where windows cannot be accessed safely and practicably by other means and where the height of suspension does no exceed 75 feet above grade or a building set back unless the use of tackle with an automatic brake is employed. c.Gold Coast Hotel and Casino, window cleaning operations, employees were swaying the boatswain's chair around the rooms overhang wall to clean two windows from the same drop down point. Reference: ANSI/IWCA I-14.1 - 2001, "Window Cleaning Safety", Section 5.6.9: No window cleaner shall attempt to clean any surface beyond his reach. Swinging, swaying or any other maneuver to increase the work area shall be prohibited. d.Gold Coast Hotel and Casino, window cleaning operations, a written service plan was not developed and readily available to the building owner, window cleaners, and emergency and enforcement authorities. Reference: ANSI/IWCA I-14.1 - 2001, "Window Cleaning Safety", Section 1.7: A written plan developed by the window cleaning contractor shall be provided that will inform the building owner or their operating agents when windows to be cleaned are located in areas where workersmay utilize suspended equipment or; where workers are exposed to falls or; where the public may be exposed to overhead work. The plan shall include among its conditions the identification of hazardous areas, drop zones, safety features and areas requiring public protection. One feasible and acceptable method of abatement would be to ensure that the requirements of ANSI/IWCA I-14.1 - 2001 are followed which were specifically developed for employee safety during window cleaning operations.
More inspections at Executive Window Cleaning & High Reach Specialist
View Executive Window Cleaning & High Reach Specialist's full OSHA safety record →
More inspections in this industry (NAICS 561790)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308701143.