CANTON, OH —
OSHA Inspection: U S CASTING COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of U S CASTING COMPANY in 722 MULBERRY ROAD SE, CANTON, OH 44707 (NAICS 331513). OSHA activity number 308734094.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U S CASTING COMPANY
- Site address
- 722 MULBERRY ROAD SE
- City
- CANTON
- State
- OH
- ZIP
- 44707
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- SIC code (legacy)
- 3325
- Employees
- 38
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 15, 2005
- Abate by
- Sep 17, 2005
- Penalty
- Initial $7,000 · Current $4,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to water/metal explosions from inadequate furnace rebuilding and sintering procedures: a) On February 22, 2005, a worker was fatality burned during sintering operations on the Pillar MK8 induction furnace. The ground leak detection system was not installed properly and the temperature of the heat was not monitored during the sintering process. The furnace bridged and exploded with molten metal erupting onto the employee. b) On June 24, 2005, The Inductotherm VIP Dual Trak 1500-5CR induction furnace ruptured during the sintering process. The wrong type of refractory material was used to line the furnace and the ground leak detection system was repeatedly overridden. The furnace exploded with molten metal erupting out and through the bottom side onto the floor. Among other means, acceptable and feasible means of abatement include, but are not limited to the following: 1. Follow the furnace and refractory manufactures' recommendations for furnace rebuilding; 2. Install the ground leak detection system in accordance with manufactures' recommendations; 3. Monitor the metal temperature continuously during sintering operations; 4. Follow the furnace manufactures' recommendations for preventing bridging;
Recent events (2)
- — F (S) $4500.00
- — Z (S) $7000.00
More inspections at U S Casting Company
View U S Casting Company's full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308734094.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.