WASHINGTON, DC —
OSHA Inspection: SUPERIOR IRON WORKS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of SUPERIOR IRON WORKS in 131 M STREET, NE, WASHINGTON, DC 20001 (NAICS 238190). OSHA activity number 308762822.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPERIOR IRON WORKS
- Site address
- 131 M STREET, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20001
- Mailing
- 45034 UNDERWOOD LANE, UNIT 100, STERLING, VA 20166
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- SIC code (legacy)
- 1791
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Jun 16, 2005
- Abate by
- Jun 21, 2005
- Penalty
- Initial $525 · Current $525
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a tipover hazard: (a) 6th Floor - The operator of a Komatsu power industrial truck (PIT), serial no. 585137A, did not have his seat belt fastened while using the PIT to lift and transport steel beams, on or about 06/13/2005. Among other methods, one feasible and acceptable abatement method to correct the hazard is establish and enforce the requirement for operators of powered industrial trucks which are equipped with operator restraint devices or seat belts to use the devices as stipulated in the current versions of ANSI B56.1, consensus standard for powered industrial trucks; ASME/ANSI B56.1a-1989 Addenda to ASME/ANSI B56.1-1988, and ASME B56.1-1993 Standard for Low Lift and High Lift Trucks. In addition, seat belts have been supplied by many manufacturers of counterbalanced, center control, high lift trucks which have a sit-down nonelevating operator position. Also, some manufacturers have instituted retrofit programs
Recent events (2)
- — I (O) $525.00
- — Z (S) $525.00
1910.178 L01
- Issued
- Jun 16, 2005
- Abate by
- Jul 7, 2005
- Penalty
- Initial $525 · Current $525
Recent events (2)
- — I (O) $525.00
- — Z (S) $525.00
More inspections at Superior Iron Works